2. WIRING
2.5.2
How to connect the transducer cables
1. Remove the transceiver unit cover.
2. Connect the cables from the transducer referring to the cable no. labeled on the
chassis and connector no. labeled on each PC board. Connect the HIF connector
of the cable from the junction box to the TRX board on the transceiver unit.
3. Arrange the cables in numerical order and fix them with the cable clamp.
4. Remove the metal fixing which secured the transducer cables to the hull unit.
2.5.3
How to connect the processor unit
Connect the LAN connector to the CN-B103 port.
2.5.4
Power cable
Connect the power cable DPYCY-1.5 (or equivalent) to TB-B101 of the transceiver
unit. Fabricate the power cable as shown below.
FV2-4 x 2
Seal cut end with
insulated tape.
2-10
140
Anticorrosive sheath
30
Cores
Set and secure vinyl
sheath in clamp.
Seal cut end with
insulated tape.