Color scanning sonar
Hide thumbs Also See for FSV25:

Advertisement

Desktop installation, no keyboard fixture
1. Drill four mounting holes of 5 mm diameter, referring to the outline drawing at the
back of this manual.
2. Fix the unit with screws (M4, 4 pcs.) from under side of the desktop. (Supply the
screws locally. Make sure the screws are of a sufficient length for the thickness of
the desktop.)
Flush mount (option)
Use the optional flush mount kit (Type: FP03-09870, Code No.: 008-535-630) to
mount the sub control unit.
Name
Mounting plate
Hex nut
Wing screw
Pan head screw
1. Prepare a hole in the mounting location referring to the outline drawing at the back
of this manual.
2. Set the unit to the hole.
3. Attach the mounting plate to the unit with four screws from the rear side.
4. Screw the wing screw to each mounting plate and then insert hex bolt to each wing
screw.
5. Fasten each wing screw and then fasten the hex nuts.
Hex nut
Wing screw
Screw holes
Type
03-163-7531
100-306-261
M5
000-863-108
M540
000-162-682-10
M412
000-163-192-10
1. HOW TO INSTALL THE SYSTEM
Screw holes
Code No.
Qty
4
4
4
4