Remove the hot-plug drive.
4.
To replace the component, reverse the removal procedure.

Access panel

WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION: To prevent damage to electrical components, take the appropriate anti-static
precautions before beginning any installation, removal, or replacement procedure. Improper
grounding can cause electrostatic discharge.
CAUTION: Do not operate the server for long periods with the access panel open or
removed. Operating the server in this manner results in improper airflow and improper cooling
that can lead to thermal damage.
To remove the component:
Power down the server (on page 27).
1.
If you are performing a non-hot-plug procedure, remove all power:
2.
Disconnect each power cord from the power source.
a.
Disconnect each power cord from the server.
b.
Do one of the following:
3.
Extend the server from the rack (on page 27).
o
Remove the server from the rack (on page 30).
o
If the locking latch is locked, use a T-15 Torx screwdriver to unlock the latch.
4.
Open the locking latch.
5.
The access panel slides back, releasing it from the chassis.