Installation

4
12

Read instructions

2
?
Cell
1
SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL
IMPORTANT: This unit draws air in from
atmosphere and you must ensure that any
emissions from any other systems such as gas or
oil boilers, do not contaminate the air entering the
heatSava product. Therefore, before installation,
consider where the external cowl will be located
in relation to any boiler flues etc. Externally, you
must ensure that the unit is positioned a minimum
distance away of; 1 metre horizontally, 1 metre
below or 3 metres above any boiler flue etc.
In kitchens, if the unit has to be fitted above a
cooker, it must be installed a minimum distance
of 650mm above electric cookers and 750mm
above gas cookers, and not have a pullcord fitted.