Gold Standard After Sales Service In the unlikely event of any on-site installation problems or queries regarding the EnviroVent heatSava, just call our hotline number. We will take your details and appoint a regional installation manager to call you back to discuss the problem. In the majority of cases, the problem can be resolved over the phone.
Page 3
Technical Specifications Unit Dimensions Rear Assembly (Extract Fan) Centre Assembly (Electronics) Front Cover Fan Adaptor Assembly (Supply Fan) Cowl End Heat Cell AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY...
Page 4
Technical Specifications Heat Cells Options Wall Depth mm Cell Order Size mm 100 - 330 331 - 430 431 - 500 501 - 600 SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL...
Wiring Diagrams Mains - This unit must be earthed Connect 2 core & earth cable into existing wiring AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY...
Page 6
Wiring Diagrams SELV - This unit must be earthed 2 core 2 core & earth SELV Connect 2 Connect 2 core cable core & earth from SELV cable to box into unit existing wiring SELV Box 2 core Power Supply 2 core &...
Page 7
Therefore, before installation, consider where the external cowl will be located in relation to any boiler flues etc. Externally, you must...
Page 8
Safety Electrical Assembly When wiring the unit in, a suitable Connect 2 core Power disconnect device such as a fused spur & earth cable into Board Supply should be used, do not use a plug. The existing wiring means of disconnecting the unit from the mains power supply must be incorporated in the fixed wiring in accordance with the wiring rules.
Page 9
Box Contents 1 heatSava Unit 5 Halo 2 Heat Cell 6 Wall Seal 3 Instructions Guide 7 Fixing Template 4 SELV (optional) 8 Fixing Kit AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY...
Page 10
Box Contents Description Quantity Item heatSava Unit Heat Cell Instructions Guide SELV (optional) Halo (Wall Kit Contents) Wall Seal Fixing Template Fixing Kit 8G X 2.0” - (Fixing Kit Contents) Red Wall Plugs - (Fixing Kit Contents) Terminal Block (Spare)
Page 11
Tools Checklist (Not supplied) Description Item Core Drill Electric Screwdriver Long & Short Screwdriver Small Terminal Screwdriver Spirit Level Cutting Pliers Long Nose Pliers Ladder Solvent Cement Silicone AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY...
Pullcord (Manual) The heatSava has been engineered with intelligent controls The heatSava comes complete with a pull cord to activate the to think for itself, meaning that you don’t need to press any boost if required. Pull once to activate the boost and once to buttons or light switches to turn it on.
Pre-Installation Introduction Heat Cell Orientation Designed for through the wall installation, the heatSava is ideal When fitting the heat cell into a wall, ensure that the cowl end is for both refurbishment and new build properties. The outside correctly orientated with the end always facing down. (Fig 4.)
Page 14
(option 1). If installing into an carefully before determining the position existing wall sleeve which is located near to and cell size suitable for the unit. the ceiling, the heatSava can be installed horizontally or vertically (options 2-4). 20mm 20mm...
• If the fixing surface is of poor quality and holes ‘B’ cannot be used, then use holes ‘A’. • To access holes ‘A’ the unit needs to be disassembled (see page 23). heatSava 100 or 150? 107mm, 117mm, 158mm, 162mm? See pages 17-19 for seal or sleeve installation...
Page 16
Installation SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL...
Page 17
Installation Solvent Cement (not supplied) AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY...
Page 18
Installation Rubber Wall Seal - Choose rubber wall seal or wall sleeve installation. 117mm or 162mm Ø SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL...
Page 19
Installation Solvent Cement 117mm or 162mm Ø AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY...
Page 20
Installation Wall Sleeve Wall sleeve not supplied 99mm (100) or 149mm (150) Ø overall 100mm or 150mm Ø internal (min) 107mm or 158mm Ø Use existing sleeve or insert new sleeve into wall. Cement Wall sleeve Apply cement around sleeve and insert through wall. SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL...
Page 21
Installation Pullcord - See page 13 for pullcord options. Option 3 & 4 Option 1 & 2 Fit cover AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY...
Page 22
Installation SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL...
Page 23
Installation External Silicone (not supplied) Installation Completed AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY...
Page 24
Installation OPTION A Front assembly: Remove badge and screw Fan adaptor: Remove 4 screws SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL...
Page 25
Installation Cell assembly: Remove 4 screws Electronics lid: Remove 3 screws AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY...
Page 26
Installation Disconnect fan Centre assembly: Remove 6 screws SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL...
Page 27
Installation heatSava 100 or 150? 107mm, 117mm, 158mm, 162mm? Drill holes ‘A’. See pages 17-19 for seal or sleeve installation Use holes ‘A’ and fix rear assembly to wall. Fix ‘6’ to wall then put assembly back together. Reverse steps 7-24 from page 15...
Cleaning & Maintenance Cleaning General cleaning of the vents and cells should be every 6 months max, or as required, as environments will vary. Service Maintenance Intervals General maintenance should ideally take place every 12 months and should be carried out only by a competent tradesperson adhering to the instructions.
Page 29
Cleaning & Maintenance AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY...
Page 30
Cleaning & Maintenance Damp cloth Soft brush Vacuum SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL...
Guarantee The EnviroVent heatSava is covered by a full 5 year warranty which will benefit the occupier over many years. What should I do if I have a problem? If, after thoroughly reading this booklet, you feel that your heatSava is not working correctly, you can telephone 0845 27 27 810 (operational from 8:00am to 5:30pm Monday to Friday), and ask for technical assistance.
Page 32
EnviroVent Ltd EnviroVent House Hornbeam Business Park Harrogate HG2 8PA 01423 810 810 info@envirovent.com www.envirovent.com Due to our policy of continuous innovation and improvement EnviroVent reserves the right to alter products specification and appearance without notice.
Need help?
Do you have a question about the heatSava and is the answer not in the manual?