Execution Commands; Ac (Apply Changes); Wr (Write); Re (Restore Defaults) - Digi S6B User Manual

Wi-fi rf module
Table of Contents

Advertisement

AT commands

Execution commands

The location where most AT commands set or query register values, execution commands execute an
action on the device. Execution commands are executed immediately and do not require changes to
be applied.

AC (Apply Changes)

Applies changes to all command registers and applies queued command register values. For example,
changing the serial interface rate with the BD command does not change the UART interface rate
until changes are applied with the AC command. The CN command and 0x08 API command frame also
apply changes.
Parameter range
N/A
Default
N/A

WR (Write)

Writes parameter values to non-volatile memory so that parameter modifications persist through
subsequent resets.
Note
Once you issue a WR command, do not send any additional characters to the device until after
you receive the OK response. Use the WR command sparingly to preserve flash.
Parameter range
N/A
Default
N/A

RE (Restore Defaults)

Restore device parameters to factory defaults.
Parameter range
N/A
Default
N/A

FR (Software Reset)

If you issue FR while the device is in Command Mode, the reset effectively exits Command mode.
Resets the device. The device responds immediately with an OK and performs a software reset
approximately 2 seconds later.
Parameter range
N/A
XBee Wi-Fi RF Module User Guide
Execution commands
180