Product Specific And Important Safety Information; Appliance Certification; Btu Specifications; High Altitude Installations - Monessen Hearth AVFL60NIP Installation Manual

Artisan series
Hide thumbs Also See for AVFL60NIP:
Table of Contents

Advertisement

1

Product Specific and Important Safety Information

A. Appliance Certification
MODEL: AVFL60NIP, AVFL60PIP
LABORATORY: CSA
TYPE: Unvented Room Heaters
STANDARD: ANSI Z21.11.2.2013
This product is listed to ANSI standards for "Unvented
Room Heaters" and applicable sections of "Gas Burning
Heating Appliances for Manufactured Homes" and "Gas
Fired Appliances for Use at High Altitude."
NOTICE: This installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in
the U.S.A.
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance. It should not be
factored as primary heat in residential heating calculations.
B. BTU Specifications
Models
AVFL60NIP
(0-4500 FT)
AVFL60PIP
(0-4500 FT)
NOTE: For LP models an external regulator is required
to reduce supply pressure to a maximum of 13" w.c.
GAS PRESSURES
Inlet Minimum
Inlet Maximum
Regulator Pressure
Setting
Pilot Regulator
4
Minimum
Maximum
Input
Input BTU/h
BTU/h
38,000
25,000
37,000
29,000
NATURAL
PROPANE (LP)
5.0" w.c.
11.0" w.c.
10.5" w.c.
13.0" w.c.
3.5" w.c.
10" w.c.
3.5" w.c.
Monessen • AVFL60 Installation Manual • 4605-901 Rev. A • 05/17
C. High Altitude Installations
NOTICE: If the heating value of the gas has been reduced,
these rules do not apply. Check with your local gas utility
or authorities having jurisdiction.
When installing above 4500 feet elevation: Reduce input
rate 4% for each 1000 feet above 4500 feet.
Check with your local gas utility to determine proper
orifice size.
D. Non-Combustible Materials Specification
Material which will not ignite and burn. Such materials are
those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in
a Vertical Tube Furnace at 750 ºC shall be considered
non-combustible materials.
E. Combustible Materials Specification
Materials made of or surfaced with wood, compressed pa-
per, plant fibers, plastics, or other material that can ignite
and burn, whether flame proofed or not, or plastered or
unplastered shall be considered combustible materials.
Orifice
Size
F. Electrical Codes
(DMS)
NOTICE: This appliance must be electrically wired
#44
and grounded in accordance with local codes or, in the
#54
absence of local codes, with National Electric Code
ANSI/NFPA 70-latest edition or the Canadian Electric
Code CSA C22.1.
• A 110-120 VAC circuit for this product must be pro-
tected with ground-fault circuit-interrupter protection,
in compliance with the applicable electrical codes,
when it is installed in locations such as in bathrooms
or near sinks.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Avfl60pipArtisan seriesAvfl60cfvcAvfl60tki

Table of Contents