Product Specific Information; Firebox Certification; Btu Specifications - Monessen Hearth BUF32A Owner's Manual

Vent-free firebox
Hide thumbs Also See for BUF32A:
Table of Contents

Advertisement

2

Product Specific Information

A. Firebox Certification
MODELS: BUF32A, BUF36A, BUF42A
BUF32-T, BUF36-T, BUF42-T
BUF32-H, BUF36-H, BUF42-H
LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE: Ventless Firebox Enclosures for Gas-Fired
Unvented Gas Log Type Room Heaters
STANDARD: CSA/ANSI Z21.91:20
This product is listed to ANSI standards for "Ventless Gas
Firebox Enclosures for Gas-FIred Unvented Gas Log
Type Room Heaters".
NOTICE:
This installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1/NFPA 54.
Note:
Smoke, carbon monoxide or combination alarms
Alarm manufacturers recommend that alarms be kept at
least 15 ft. to 20 ft. laterally away from fuel-burning sources.
Installing the alarm closer than 15 ft. will not harm the
alarm, but may increase the frequency of nuisance alarms.
Mounting alarms on the wall versus the ceiling will further
reduce nuisance alarms.
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance. It should not be
factored as primary heat in residential heating calculations.
Installation and service of this appliance should
be performed by qualified personnel. Hearth
& Home Technologies recommends HHT
Factory Trained or NFI certified professionals.
WARNING: This product and the
fuels used to operate this product (liquid
propane or natural gas), and the products
of combustion of such fuels, can expose
you to chemicals including benzene, which
is known to the State of California to cause
cancer and reproductive harm. For more
information go to: www.P65Warnings.
ca.gov.
6
Monessen • BUF32/36/42 Owner's Manual • 4139-900 • Rev A • 01/21
B. BTU Specifications
This product is for use ONLY with a listed decorative
"Gas-Fired Unvented Decorative Room Heaters".
Model(s)
BUF32 A/T/H
(0-2000 FT)
BUF36 A/T/H
(0-2000 FT)
BUF42 A/T/H
(0-2000 FT)
Altitude
Maximum
Allowable
BTU/hr
30,000
40,000
40,000