Electrical Information

A. General Information
WARNING! Risk of Shock or Explosion! DO NOT wire
110-120 VAC to the valve or to the appliance wall switch.
Incorrect wiring will damage controls.
NOTICE: This appliance must be electrically wired and
grounded in accordance with local codes or, in the absence
of local codes, with National Electric Code ANSI/NFPA
70-latest edition.
• Wire the appliance junction box to unswitched 110-
120 VAC. This is required for proper operation of the
appliance.
• A 110-120 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in
compliance with the applicable electrical codes, when
it is installed in locations such as in bathrooms or near
sinks.
• Low voltage and 110/120 VAC voltage cannot be shared
within the same wall box.
Electrical Service and Repair
WARNING! Risk of Shock! Label all wires prior to dis-
connection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.
WARNING! Risk of Shock! Replace damaged wire with
type 105º C rated wire. Wire must have high temperature
insulation.
Accessories Requirements
• This appliance may be used with a wall switch, or optional
wall mounted thermostat and/or a remote control.
Wiring for optional Hearth & Home Technologies approved
accessories should be done now to avoid reconstruction.
Follow instructions that come with those accessories.
Junction Box Installation
WARNING! Risk of Shock! Label all wires prior to dis-
connection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.
WARNING! Risk of Shock! Replace damaged wire with
type 105° C rated wire. Wire must have high temperature
insulation.
Junction Box Wiring
1. This should be done before framing the fireplace. Wire
the receptacle into an electrical circuit.
2. The junction box cover has a Romex style strain relief
connector located in the Owner's Manual. After con-
necting the wires, route the wire leads through this
connector. Refer to the wiring diagram in Figure 6.2.
Monessen • AVFL60 Installation Manual • 4605-901 Rev. A • 05/17
Figure 6.1 Cover Plate for Junction Box
WARNING
Electrical connections should only be performed
by a qualified, licensed electrician. Main power
must be off when connecting to main electrical
power supply or performing service. All wiring
shall be in compliance with all local, city and
state codes. The appliance, when installed,
must be electrically grounded in accordance
with local codes or in the absence of local
codes, with the National Electrical Code ANSI/
NFPA 70 (latest edition) and Canadian Electrical
Code, CSA C22.1.
WARNING
Do not connect wall switch to 110 V circuit.
Label all wires before disconnecting when
servicing controls. Wiring errors can cause
improper and dangerous operation.
Junction Box
Figure 6.2 - Junction Box Wiring Diagram