Monessen Hearth AVFL60NIP Installation Manual
Monessen Hearth AVFL60NIP Installation Manual

Monessen Hearth AVFL60NIP Installation Manual

Artisan series
Hide thumbs Also See for AVFL60NIP:

Advertisement

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
NOTICE: DO NOT discard this manual!
ARTISAN
SERIES
Models:
AVFL60NIP
AVFL60PIP
This is an unvented gas-fired heater. It uses air
(oxygen) from the room in which it is installed.
Provisions for adequate combustion and ventil-
ation air must be provided. Refer to Page 6.
In the Commonwealth of Massachusetts
installation must be performed by a licensed
plumber or gas fitter.
See Table of Contents for location of
additional Commonwealth of Massachusetts
requirements.
Installation Manual
Installation and Appliance Setup
Monessen • AVFL60 Installation Manual • 4605-901 Rev. A • 05/17
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
• DO NOT store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions.
- If you cannot reach your gas supplier, call
the fire department.
• Installation and service must be performed
by a qualified installer, service agency, or the
gas supplier.
DO NOT install this unit in a bedroom or
bathroom. Please refer to page 6 Section F for
proper unit placement.
1

Advertisement

Table of Contents
loading

Summary of Contents for Monessen Hearth AVFL60NIP

  • Page 1 Models: • DO NOT store or use gasoline or other flam- mable vapors and liquids in the vicinity of this AVFL60NIP or any other appliance. AVFL60PIP • What to do if you smell gas - DO NOT try to light any appliance.
  • Page 2: Table Of Contents

    Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. • CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. •...
  • Page 3: Installation Standard Work Checklist

    Installer: Model Dealer/Distributor Phone # (circle one): AVFL60NIP, AVFL60PIP Serial #: WARNING! Risk of Fire or Explosion! Failure to install appliance according to these instructions could lead to a fire or explosion. Appliance Install Sections 2 and 4 (Pg. 5 & 12) ___________________________ Verified that the chase is insulated and sealed.
  • Page 4: Product Specific And Important Safety Information

    Product Specific and Important Safety Information A. Appliance Certification C. High Altitude Installations NOTICE: If the heating value of the gas has been reduced, MODEL: AVFL60NIP, AVFL60PIP these rules do not apply. Check with your local gas utility LABORATORY: CSA or authorities having jurisdiction.
  • Page 5: Getting Started

    Getting Started C. Inspect Appliance and Components A. Design and Installation Considerations Installation MUST comply with local, regional, state and • Carefully remove the appliance and components from national codes and regulations. Consult insurance carrier, the packaging. local building inspector, fire officials or authorities having •...
  • Page 6: Getting Started

    D. Getting Started 4. Plumb gas line. Gas line may be run either through bottom of unit or left side. There is no right side access. Verify that all listed parts have been received. You should Refer to the Connect the Gas (page 16, Figure 5.4) have the following: section found in this manual.
  • Page 7 • Never obstruct the front opening of the unvented fire- place or restrict the flow of combustion and ventilation air. Counter Fireplace • Minimize modifications to existing construction. Refer to Figure 2.2 below for location suggestions. • Do not install in the vicinity where gasoline or other flammable liquids may be stored.
  • Page 8: Framing And Clearances

    Framing and Clearances A. Fireplace and Framing Dimensions 67-3/16” Corner Framing Actual Rough 67-3/16” Opening 16-1/8” 18” Depth 95” 55-7/8” Rough Opening Width Rough 6” Opening Actual Height 36-3/8” 16” 29-3/4” 6-7/8” 51” View 2-3/8” 1-7/8” 11” 55-3/8” 7” Actual Electrical Figure 3.1 Fireplace and Framing Dimensions ONLY NON-COMBUSTIBLE...
  • Page 9: Clearances And Height Requirements

    WARNING The dimensions shown in Figures 3.4 and 3.5 are minimum clearances to maintain when installing this heater. Left and right clearances are determined when facing the front of the heater. Follow these instructions carefully to ensure safe installation. Failure to follow instructions exactly can create a fire hazard.
  • Page 10: Good Faith Wall Surface Tv Guidelines

    C. Good Faith Wall Surface TV Guidelines Good Faith Guidelines for TV Installations above a Typical Gas Fireplace TV recessed into the wall TV on the wall Noncombustible Mantel (required) Measured from top 6” Min. of rebox opening. 4” Min. 4”...
  • Page 11: Constructing The Appliance Chase

    E. Floor Protection D. Constructing the Appliance Chase NOTICE: Install appliance on hard metal or wood surfaces A chase is a vertical box-like structure built to enclose the gas appliance. extending full width and depth. DO NOT install directly on carpeting, vinyl, tile or any combustible material other NOTICE: Construction of the chase may vary with the type than wood.
  • Page 12: Appliance Preparation

    Appliance Preparation A. Securing and Leveling the Appliance WARNING! Risk of Fire! Prevent contact with: • Sagging or loose insulation 55-3/8" • Insulation backing or plastic MOUNTING • Framing and other combustible materials POINTS Block openings into the chase to prevent entry of blown- in insulation.
  • Page 13: Installing Non-Combustible Facing Material

    B. Installing Non-Combustible Facing Material Setting the Fireplace into the Framing The left and right nailing tabs were designed as a means WARNING! Risk of Fire! to ensure the fireplace is mounted flush with the framing • Follow these instructions exactly. materials.
  • Page 14: Gas Information

    Gas Information A. Fuel Type Note: Have the gas supply line installed in accordance with local codes, if any. If not, follow ANSI 223.1. Installation • This appliance is equipped for either natural or propane should be done by a qualified installer approved and/or gas.
  • Page 15 Battery Valve Backup Module Buttons Control Module Adapter Figure 5.2 Valve Access Monessen • AVFL60 Installation Manual • 4605-901 Rev. A • 05/17...
  • Page 16: Connect To Gas

    D. Connect to Gas When an appliance is connected to a fixed piping sys- tem, the installation must conform with local codes,or in NOTICE: A qualified gas appliance installer must connect the absence of local codes with the National Fuel Gas the heater to the gas supply.
  • Page 17: Valve Access

    E. Valve Access F. Check Gas Pressure The valve and controls are located in the appliance con- Check the gas pressure with the appliance burning and trol box. See Figure 5.4. the control set to HIGH. The control box and controls can be accessed by lifting Open control access door at bottom front of unit to find engine assembly and shown in Figure 5.4.
  • Page 18: Gas Connection

    G. Gas Connection Light the appliance. It will take a short time for air to purge from lines. When purging is complete the appliance will • Refer to Figure 5.7 for location of gas flex line access in light and operate normally. appliance.
  • Page 19: Electrical Information

    Electrical Information A. General Information WARNING! Risk of Shock or Explosion! DO NOT wire 110-120 VAC to the valve or to the appliance wall switch. Incorrect wiring will damage controls. NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition.
  • Page 20: Wiring Requirements

    B. Wiring Requirements NOTICE: Batteries should only be used as a power source in the event of an emergency power outage. Batteries Intellifire™ Plus ODS Ignition System Wiring should not be used as a primary long-term power source. Battery polarity must be correct when installing batteries. •...
  • Page 21: Control Module

    JUNCTION BOX CONTROL MODULE Figure 6.4 Wiring Diagram Monessen • AVFL60 Installation Manual • 4605-901 Rev. A • 05/17...
  • Page 22: Final Installation

    Final Installation A. Dome Light Bulb Installation B. Black Magic Glass Installation The Black Magic Glass liner is packaged and shipped with the unit. Before install, remove the glass panels and Turn OFF the main power supply before perform- place on a flat, clean surface and inspect for damage. ing any service work on the unit, including install- NOTE: Before beginning installation remove the two L ing or replacing light bulbs.
  • Page 23: Installation Of Air Deflection Glass

    C. Installation of Air Deflection Glass Both bags may be used to cover the entire floor and burner. We advise against using additional fireglass as too much NOTE: If installing optional driftwood logs be sure to can cut off the proper amount of air the burner needs to install log pin brackets prior to installing air deflection burn cleanly.
  • Page 24: Placement Of Optional Logs

    WARNING The positioning of the logs is critical to the safe and clean operation of this heater. Sooting and other problems may result if the logs are not properly and firmly positioned in the appliance. Never add additional logs or embellishments such as pine cones, vermiculite or rock wool to the heater.
  • Page 25 3. The front driftwood log does not utilize a pin bracket. This log can be placed behind the front deflection glass with the area marked on the figure below. THIS LOG CAN ONLY BE PLACED WITHIN THIS AREA. The log cannot be placed on the burner area. It can be adjusted left to right as desired.
  • Page 26: Lighting Instructions (Ipi)

    G. Lighting Instructions (IPI) FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fi re or explosion may result causing property damage, personal injury or loss of life. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas sup- A.
  • Page 27: Finishing

    Finishing A. Facing and Finishing Instructions • Finishing Around Perimeter of Unit (Install Option WARNING! Risk of Fire! Comply with all minimum clear- Gypsum wallboard (drywall) joints can be finished up to ances to combustibles as specified. Framing closer than the the perimeter of the left, right and bottom edge of the unit minimums listed must be constructed entirely of noncom- flush with the face.
  • Page 28 WARNING! Risk of Fire! DO NOT apply combustible In extreme cases, lab tests have shown yellow pigments materials beyond the minimum clearances. Comply with fading out of paints over time due to heat. Vent run and all minimum clearances to combustibles as specified in installation location will have an effect on wall temperature and fading.
  • Page 29: Operation During A Power Outage

    B. Operation During A Power Outage To Return to Operation Using Electrical (AC) Power CAUTION! Risk of Overheating! Component heat shield The IntelliFire™ Plus ODS intermittent pilot ignition system MUST be installed before operating appliance. Electrical comes with a battery backup system that enables the components will be damaged.
  • Page 30: Detailed Component Operating Instructions.-Intellifire Plus

    C. Detailed Component Operating Instruc- 5. Module Reset tions— Intellifire™ Plus ODS This module may lock-out under certain conditions. When this occurs, the appliance will not ignite or Control Module Operation respond to commands. The module will go into 1. The control module has an ON/OFF/REMOTE selector lock-out mode by emitting three audible beeps, then switch that must be set.
  • Page 31: Troubleshooting

    D. Troubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a qualified service technician in the diagnosis of a problem and the corrective action to be taken. This troubleshooting guide can only be used by a qualified service technician. Contact your dealer to arrange a service call by a qualified service technician.
  • Page 32 Intellifire™ Plus Ignition System - (continued) Symptom Possible Cause Corrective Action A. A shorted or loose connection in flame Verify all connections to wiring diagram in manual. Verify 4. Pilot lights but contin- sensing rod. connections underneath pilot assembly are tight. Verify ues to spark, and main flame sense or igniter wires are not grounding out to metal burner will not ignite.
  • Page 33: Accessories

    E. Accessories Remote Controls, Wall Controls and Wall Switches Follow the instructions supplied with the control installed to operate your fireplace: For safety: • Install a switch lock or a wall/remote control with child protection lockout feature. • Keep remote controls out of reach of children. Contact your dealer if you have questions.
  • Page 34 Monessen, a brand of Hearth & Home Technologies 7571 215 Street West, Lakeville, MN 55044 www.monessenhearth.com Please contact your Monessen dealer with any questions or concerns. For the location of your nearest Monesen dealer, please visit www.monessenhearth.com Monessen • AVFL60 Installation Manual • 4605-901 Rev. A • 05/17...

This manual is also suitable for:

Avfl60pipArtisan seriesAvfl60cfvcAvfl60tki

Table of Contents