Thrush Aircraft S2R-R1340 Maintenance Manual page 69

Single cockpit and dual cockpit
Table of Contents

Advertisement

THRUSH AIRCRAFT, INC – MODEL S2R-R1340
6. Close the bleeder valve and place the
plastic tube on the other bleeder
valve.
7. Bleed that caliper the same as above.
It should not take more than two
brake pedal strokes.
8. Close that bleeder valve and top off
Effective: 01/01/08
AIRCRAFT MAINTENANCE MANUAL
Figure 3-4: Main Landing Gear Hydraulics
the
master
reservoir.
9. Dispose of the hydraulic fluid bled
into the container properly. DO NOT
reuse this hydraulic fluid, as it may be
contaminated.
cylinder
hydraulic
3- 5