Installation and commissioning
8

Mount and connect approach barrier

.06
● For machines delivered without table, plate 1 (included in the accessories) must be
● Loosen screws 3 and align carrier 4 in such a way that switching plate 2 is free when the
● Connect connectors of the approach barrier on contacts 5 (red/blue) and 6 (grey/pink).
8

Checking the start inhibitor function

.07
● Switch the machine on at the main switch and tilt back the sewing head.
● The error message "Er 0 16" (on MD-4-58-220-CE) or "Error 9 (on PicoDrive P41 PD2)
● If the message does not appear, check the setting of safety switch 2.
● After the sewing head has been returned to the upright position, the machine is ready
24
2
4
3
Fig. 8 - 09
mounted underneath the table top in such a way that the switching plate 2 is fl ush with
plate 1 when the sewing head is tilted upright.
sewing head is on its side, and pressed, when the sewing head is upright.
must appear on the control panel.
for operation again.
5
6
1