transmission, no significant signal has been
received, and re-transmission of the procedure
signal has been attempted the number of
specified times but failed.
##752 TX
After transmitting PPS-NULL in ECM
transmission, DCN has been received.
##753 TX
After transmitting PPS-NULL in ECM
transmission, re-transmission of the procedure
signal has been attempted the number of
specified times but failed, or T5 time-over (60
sec.) has occurred.
##754 TX
After transmitting PPS-NULL in ECM
transmission, re-transmission of the procedure
signal has been attempted the number of
specified times but failed.
##755 TX
After transmitting PPS-MPS in ECM
transmission, no significant signal has been
received, and re-transmission of the procedure
signal has been attempted the number of
specified times but failed.
##757 TX
After transmitting PPS-MPS in ECM
transmission, DCN has been received.
##758 TX
After transmitting PPS-MPS in ECM
transmission, re-transmission of the procedure
signal has been attempted the number of
specified times but failed, or T5 time-over (60
sec.) has occurred.
##759 TX
After transmitting PPS-MPS in ECM
transmission, re-transmission of the procedure
signal has been attempted the number of
specified times but failed.
##760 TX
After transmitting PPS-EOM in ECM
transmission, no significant signal has been
received, and re-transmission of the procedure
signal has been attempted the number of
specified times but failed.
##762 TX
After transmitting PPS-EOM in ECM
transmission, DCN has been received.
##763 TX
After transmitting PPS-EOM in ECM
transmission, re-transmission of the procedure
signal has been attempted the number of
specified times but failed, or T5 time-over (60
sec.) has occurred.
##764 TX
After transmitting PPS-EOM in ECM
- Try a higher transmission level.
- Increase the period of time of the T5
time-over.
- Try a higher transmission level.
- Try a higher transmission level.
- Try a higher transmission level.
- Increase the period of time of the T5
time-over.
- Try a higher transmission level.
- Try a higher transmission level.
- Try a higher transmission level.
- Increase the period of time of the T5
time-over.
- Try a higher transmission level.
16 / 76

Advertisement