Lennox 11U61 Setup And Installation Manual page 19

Icomfort wi-fi flex, touchscreen programmable thermostat
Hide thumbs Also See for 11U61:
Table of Contents

Advertisement

2. From the Features screen, select system settings.
3. Touch the button of the dehumidification settings you
want to adjust; if it says de-humidifier OFF, one touch
will display a selection for OFF, MEDIUM or HIGH.
4. Selecting MEDIUM or HIGH will bring on the set-to
button.
5. When you touch the set-to button, the arrows
appear, allowing you to change to the desired
de-humidifier percentage setting.
SYSTEM SETTINGS
humidification
settings
%
40
humidifier
is ON
set to
ALL CHANGES MADE ON
THIS SCREEN ARE IN­
STANTLY SAVED.
Wi-Fi
9:39 am Aug 15, 2012
Figure 15. Humidifier Controls (Outdoor Unit)
HOW DEHUMIDIFICATION MODE WORK — NO
EXTERNAL DEHUMIDIFICATION DEVICE
NOTE - OFF, MEDIUM and HIGH dehumidification modes
are also a function of the HVAC system with NO external
dehumidification devices installed.
In OFF mode, dehumidification if off.
dehumidification
settings
OFF
de-
%
50
humidifier
MEDIUM
set to
MEDIUM
HIGH
current indoor humidity is 50%
In MEDIUM mode, dehumidification occurs if these
conditions are met and signals are present at specific
terminals:
dehumidification has been enabled on installer
settings, and
the unit is in COOL mode, and
dehumidification demand exists (RH above setpoint),
and
cooling demand exists (Y1 energized).
In HIGH mode, dehumidification occurs if all BASIC
conditions are true, except cooling demand may or may not
be present. Also note that:
Maximum over cool from cooling setpoint is 2ºF.
humidifier
display
Deadband temperature is limited to a minimum of
is ON
5ºF (instead of 3ºF in DRY or MODERATE modes)
(default is ON)
because of 2ºF overcooling.
AUXILIARY DEHUMIDIFIER — OUTDOOR UNITS
Control State
?
Auxiliary dehumidification
is controlled by
thermostat.
Auxiliary dehumidification
is controlled by dehumidi­
fication control.
19
Conditions
System must be in cooling mode and have
a call for dehumidification from the
thermostat. This will start the auxiliary
dehumidifier.
A separate wire from auxiliary dehumidifier
will need to be run to G terminal on indoor
unit control to start the blower.
Needs a dehumidification demand from the
stand-alone dehumidification thermostat and a
separate wire run to G terminal on indoor unit to
start the blower.