Okofen PE 08 Operating Manual page 165

Initial start up pellet heating system with auger delivery system or vacuum suction system for professionals
Table of Contents

Advertisement

Malfunction report
13.11 Motor extraction auger 1 - RA (Fault 5026)
Display:
Description:
Cause and Remedy:
13.12 Hopper motor (Fault 5028)
Display:
Description:
Cause and Remedy:
13.13 Emergeny OFF/ Safety temperature (Fault 5032, 5033)
Display:
Description:
Cause and Remedy:
Display:
Description:
Cause and Remedy:
13.14 Temperature Combustion chamber sensor/Flue gas sensor (Fault 5034, 5036)
Display:
Description:
Cause and Remedy:
[5026] Motor ext auger1
Storage room auger 1 motor defect – Output RA
Motor unplugged
motor is jammed
Motor defect
Thermic contact triggered
Motor not running
[5028] Hopper motor
Hopper suction fan fault. Output ZW.
Motor unplugged
Motor defect
[5032] Emergeny OFF – NOT AUS
Emergency OFF has been actuated – Input NOT-AUS
Emergency OFF
unplugged
Emergency OFF button
has been pressed
Emergency OFF defect
[5033] Safety temperature - STB
Safety temperature limiter has tripped – Input STB
Safety temperature limiter
unplugged
Safety temperature limiter
has tripped
Safety temperature limiter
defect
A 230V Output is defect
[5034] PE Ignition fault / Pellets available?
Minimum temperature Combustion chamber sensor/Flue gas sensor not rea-
ched durring the ignition phase
No pellets available
Ignition electrode defect
Ignition nozzle blocked
Plug in motor, check cable connections
Remove pellets and dust from auger and
make sure auger rotates freely
Replace motor
Let motor cool down
Check thermic contact
Plug in motor, check cable connections
Replace motor
Connect up Emergency OFF and check cab-
le connections
Reset Emergency OFF switch
Replace Emergency OFF switch
Connect up safety temperature limiter and
check cable connections
Let boiler cool down and reset safety tem-
perature limiter
Replace safety temperature limiter
Check 230V Outputs
Fill up with pellets
Check ignition electrode (approx. 200 ) re-
place if required
Clean burner plate and ignition tube
Operating Manual PELLEMATIC® PE(S)(K)(B) 10 — 56
165

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Okofen PE 08

Table of Contents