Connective pipe installation
Electric safety regulations for the initial Instal-
lation
1 For the left-hand and right-hand piping, re-
move the pipe cover from the side panel
2 For the right back and left back piping, in-
stall the piping as shown
NOTE: Both sides drainage structure is stand-
ard. For both sides drainage structure, it can
be choosen for right, left or both sides drain-
age connection. If choosing both sides drain-
age connection, another proper drain hose is
needed as there is only one drain hose offered
by factory. If choosing one side drainage con-
nection, make sure the drain hole on the other
side is well plugged.
For 9k/12k models, if choosing left-hand or
left-back piping,please choosing left side
drainage connection. The connection of the
drain hose is supposed to be done by qualified
installer in case of water leakage.
3 Bundle the tubing, connecting cable, and
drain hose with tape securely, evenly as
shown in Figure on the right
Because the condensed water from rear of
the indoor unit is gathered in ponding box
and is piped out of room Do not put any-
thing else in the box
CAUTION
Connect the indoor unit first, then the out-
door unit
Do not allow the piping to let out from the
back of the indoor unit
Be careful not to let the drain hose slack
Heat insulation should be done to the ex-
tension drain hose of indoor unit
Be sure that the drain hose is located at the
lowest side of the bundle Locating at the
upper side can cause drain pan to overflow
inside the unit
Never intercross nor intertwist the power
wire with any other wiring

Indoor unit installation

1 Pass the piping through the hole in the wall
2 Hook the indoor unit onto the upper por-
tion of installation plate (Engage the indoor
unit with the upper edge of the installation
plate) Ensure the hooks are properly seated
on the installation plate by moving it in left
and right
3 Piping can easily be made by lifting the
indoor unit with a cushioning material be-
tween the indoor unit and the wall Get it
out after finish piping
4 Press the lower left and right side of the unit
against the installation plate until hooks en-
gages with the their slots
Move and tape the
drain hose with
piping in a position
as mentioned in Fig
Below
Cover for the
right piping
Right piping
Left piping
Indoor unit
Connective cable
Drain hose
Upper Hook
Lower Hook
Cover for the
left piping
Cover for piping
Rubber plug
Left back piping
Ponding box
Pipe room
Connective pipe
Wrapping belt
9
EN
Cushioning
materiel