SELECT THE BEST LOCATION

EN
Indoor unit
There should not be any heat source or stream near the unit
There should not be any obstacles blocking the air circulation
A place where air circulation in the room is good
A place where drainage can be easily done
A place where noise prevention is taken into consideration
Do not install the unit near the door way
Ensure the spaces indicated by arrows from the wall,ceiling,fence or other obstacles
There should not be any direct sunlight If unavoidable,
sunlight prevention should be taken into consideration
Outdoor unit
If an awning is built over the unit to prevent direct sunsight or rain,be careful
that heat radiation from the condenser is not obstructed
There should not be any animal or plant which could be affected by hot air dis-
charged
Keep the spaces indicated by arrow from wall ceiling, fence or other obstacles
Do not place any obstacles which may cause a short circuit of the discharged air
Settlement of outdoor unit
Anchor the outdoor unit with a bolt and nut ø 10 or ø 8 tightly and horizontally
on a concrete or rigid mount
NOTE: The outdoor unit you purchase may be like one of the following. Install the
outdoor unit according to the dimension as indicated in the table below:
Outdoor unit dimension
mm (W × H × D)
700 × 540 × 240
685 × 430 × 260
780 × 540 × 250
760 × 590 × 285
775 × 545 × 310
845 × 700 × 320
670 × 540 × 265
ACCESSORIES
Number
Name of Accessories
1
Installation Plate
2
Clip Anchor
3
Self-tapping Screw A ST3 9x25
4
Seal (For cooling & heating models only)
5
Drain Joint (For cooling & heating models only)
Connecting pipe
6
Assembly
7
Remote controller
8
Self-tapping Screw B ST2 9x10
9
Remote controller holder
10
Air freshening filter(used to install on Air filter)
NOTE: Except the above parts provided,the other parts needed during installation you must purchase
Mounting dimensions
A (mm)
B (mm)
458
250
460
276
549
276
530
290
560
335
600
320
481
276
Liquid side
Gas side
Air inlet
5–8 (depending on models)
5–8 (depending on models)
ø 6 35
Parts you must purchase
ø 9 52
The pipe size differ from appliance
ø 9 52
Consult the technician
ø 12 7
ø 16
optional parts
W
A
Air inlet
Air outlet
Qty
1
1
1
to appliance
for the proper size
1
2
1
1