EN
1

Preliminary remarks

1.1

Safety instructions and hints

In these operating instructions, the following symbols with warnings are used:
Symbol
WARNING!
CAUTION!
NOTE
INFORMATION
1.2

Intended use

FRIAMAT fusion units are designed to apply a maximum fusion voltage of
48 V on the following:
• FRIALEN
®
• der FRIALEN
(SDR 17-7), and
• FRIAFIT
sewage fittings with HDPE sewage pipes (SDR 17-33).
®
FRIAMAT fusion units can also be used on fittings from other manufacturers
when these components bear a 24 digit barcode complying with ISO
13950:2007-03. The power ratings and technical data of both the fittings and
the FRIAMAT fusion unit must be observed (see also Section 3.9 "Technical
data").
Intended use also includes adherence to:
• all of the instructions in these operating instructions,
• the general and specific processing specifications for electrofusion
fittings, and
• the applicable accident prevention regulations, the environmental
regulations, the statutory rules, the pertinent safety provisions, and
all standards, laws, and directives applying in the country of use.
6
Danger to people.
Failure to comply can result in death or serious injury.
Danger to people.
Failure to comply can result in minor or moderate injury.
Danger to objects.
Failure to comply can result in objects damage.
Application hints and other useful information.
Failure to comply can not result in personal inury or
objects damage.
safety fittings with HDPE pressure pipes (SDR 17-7),
XL large pipe installations with HDPE pressure pipes
®
Meaning