Automatic activation of maintenance interval
The maintenance interval stored in the FRIAMAT fusion unit (default: 12
months, see also Section 7.2) is not activated automatically until after the first
fusion.
INFORMATION
The leading maintenance date is always shown on the display and may differ
from the details on the service label attached to the FRIAMAT fusion unit!
3.11
Transport/storage/dispatch
The FRIAMAT fusion unit is delivered in an aluminium transport box. This alu-
minium transport box keeps it dry and protected against moisture. The alu-
minium box should always be used to transport the device. The temperature
range for storage is -20 °C to +70 °C.
4
"Fusion" sequence
4.1
Siting, connection, and startup
Before every use, you should check that the FRIAMAT fusion unit is not dam-
aged and operates properly within the specifications. All parts must be cor-
rectly installed and all conditions fulfilled. Only then can the device operate
properly.
The FRIAMAT fusion unit can be sited and operated out of doors when it is
protected against rain and moisture.
1. The FRIAMAT fusion unit must be sited on level ground.
2. Prepare the fitting and pipes for fusion in compliance with the assembly
instructions.
3. Make sure that the fitting's contact pins are accessible for connection to
the fusion plugs.
NOTE
Danger of overheating in the cables!
Before use, all cables must always be unwound completely. This applies to the
device, fusion, and extension cables.
16