Changing The Hydraulic-System Filters And Fluid - Toro 74447TE Operator's Manual

122cm titan hd 1500 series
Table of Contents

Advertisement

Figure 71
1. Engine
g037051
2. Expansion tank
Changing the
Hydraulic-System Filters
and Fluid
Service Interval: After the first 75 hours—Change the
hydraulic-system filters and fluid.
Every 500 hours—After the initial change—change
the hydraulic-system filters and fluid when using Toro
HYPR-OIL
500 oil (change it more often under
severe conditions).
Every 250 hours—After the initial change—change
the hydraulic-system filters and fluid when using Mobil
1 15W50 fluid (change it more often under severe
conditions).
Change the filters and oil at the same time. Do not use the
oil again. Purge any air in the system after you install the new
filters and add oil. Refer to
(page
54).
Repeat the bleeding process until the oil remains at the F
C
line in the reservoir after purging. Failure to properly
OLD
perform this procedure can result in irreparable damage
to the transaxle drive system.
Removing Hydraulic-System
Filters
1. Shut off the engine, wait for all moving parts to stop,
allow the engine to cool, remove the key, and engage
the parking brake.
2. Locate the filter and guards on each transaxle-drive
system
(Figure
72).
3. Remove the 3 screws securing the filter guard and
guard
(Figure
72).
52
Bleeding the Hydraulic System
®
ULL