Skyrc D100 Instruction Manual page 22

Ac/dc dual balance charger discharger / power supply
Hide thumbs Also See for D100:
Table of Contents

Advertisement

NiMH/NiCd Battery Program
[ TIME: 00:04:04 ]
9.6V 00640mAh
NiMH/NiCd Re-Peak Mode:
Applicable to NiMH and NiCD batteries only, in re-peak mode the charger can peak-
charge the battery once, twice, or three times in a row automatically. This process is good
for confirming that the battery is fully charged and for verifying how well the battery can
accept a fast charge. A five-minute cool-down delay occurs after each re-peak charge.
IN RE-PEAK MODE, THE D100 V2 USES THE CHARGE AMPERAGE AND VOLTAGE
SETTINGS ENTERED IN CHARGE MODE.
NiMH RE-PEAK
2
START/ENTER
NiMH 1.3A 10.42V
RPC 004:04 00686
· 20
When discharging is complete, the screen will read "END:
CUTOFF-VOL" and the charger will emit a ringing sound.
The charger will display the elapsed time, end voltage and the
discharged capacity in mAh.
You can press the STOP button at any time during the
discharging process to stop the discharge process.
After selecting the correct battery type, use the INC or DEC
button to select the "RE-PEAK" mode. Press the START button
and the Re-peak cycle number 1 begins to flash on the screen.
Use the INC or DEC button to scroll through the cycle count and
set a number between 1 and 3.
Press and hold the START button for 3 seconds to start the re-
peak process.
Once the Re-Peak process has begun, the charger will display
the following real-time information: battery type, charging
current, battery voltage, elapsed time and charged capacity.
Once the Re-Peak process has completed, the screen will read
"END: RE-PEAK" and the charger will emit a ringing sound. The
charger will display the charge/discharge capacity for each
cycle. Using the + and - buttons, you can scroll through the
history data of each cycle.
D100v
2

Advertisement

Table of Contents
loading

Table of Contents