firmware update will be in progress as the preview row buttons are turned on one at a time
from left to right until all buttons are backlit constant green after approximately ONE minute.
At this point, the firmware update is complete and the mainboard will reboot itself. After the
SE-500HD finishes booting, the new version number will be displayed at the bottom right
corner of the SE-500HD startup screen, for instance V1.6.
6. The OSD fonts will be automatically updated after the Step 5 is executed and the update status
will be indicated by the LED color (green) of the preview row buttons. The machine reboots itself
after the mainboard is updated, and the BLK button will start flashing green after the reboot. The
OSD fonts update will start approximately 10 seconds after the mainboard finishes booting.
• Same version number detected: The firmware will NOT be updated and all six buttons will be
backlit green.
• Different version number detected: The startup screen on the monitor disappears and the
firmware update will be in progress as the preview row buttons are turned on one at a time
from left to right until all buttons are backlit constant green after approximately TWO minutes.
At this point, the monitor will display a four-quadrant Multiview display and this indicates that
the OSD fonts update is complete.
7. The update is finished all six buttons of the program and preview rows are respectively backlit
constant red and green. Remove the USB thumb drive and reboot the SE-500HD.
8. After the machine finishes booting and as soon as you see the Multiview screen, press the MENU
button
to
open
Use the Up/Down arrow buttons to move to the Setup option and check if the firmware is
successfully updated:
• MB Software: V1.16.1.02
• KBD Software: V1.2 (SE-500HD)
Note 1: The device will not be damaged if the USB cable or power is accidentally disconnected while
the firmware is being updated; plug the USB thumb drive back in and reboot the device to continue
the update process.
Note 2: The USB disk drive system supports FAT / FAT32 formats.
Note 3: There is no guarantee that the SE-500HD supports all USB disks. When you see all buttons of
the program and preview rows are backlit pink or greenish pink, this indicates the disk file read error.
When this occurs, please try using USB thumb drives made by other manufacturers.