Disconnect the mains power cord before you remove the Product
covers.
Remove the input signals before you clean the Product.
Use only specified replacement parts.
Use only specified replacement fuses.
The mains power service must be rated for 16 A, and if the mains
power cord is internally fused, a 10 A fuse must be fitted in the
mains power cord plug.
Have an approved technician repair the Product.
When the cover is removed, voltages more than 1.5 KV can be
present.
Properly terminate the sense leads to prevent exposure to
hazardous voltages on the sense terminals. The voltage sense
terminals are at output voltage when the two-wire function is set.
Never touch a lead or terminal on the Product when a dangerous
voltage is present.
Do not use low voltage spade-terminated leads to connect to a
hazardous voltage (>32 V ac rms or >42 V pk). A general purpose
probe kit is supplied with the Product for safe measurement at
higher voltages.
Do not touch exposed metal on banana plugs, they can have
voltages that could cause death.
Do not use test leads if they are damaged. Examine the test leads
for damaged insulation and measure a known voltage.
Use the correct terminals, function, and range for measurements.
Keep fingers behind the finger guards on the probes.
Connect the common test lead before the live test lead and
remove the live test lead before the common test lead.
Remove signal connections before the protective ground
connection is removed. For example, the mains power cord must
be connected when the signal leads are connected.
Do not connect or disconnect signal leads while they are
connected to a hazardous voltage or current source.
Disconnect power and discharge all high-voltage capacitors
before you measure resistance, continuity, capacitance, or a
diode junction.
Before the Product is connected to a circuit to make a current
measurement, check the fuses on the Product and turn off the
power to the circuit.
Limit operation to the specified measurement category, voltage,
or amperage ratings.
Do not connect measurement probes directly to mains.
Complete safety tests after a part replacement to make sure the
Product is safe.
Do not connect an external capacitance greater than 50 nF to the
Product terminals.