Philips EL1.1U Service Manual page 22

Table of Contents

Advertisement

EN 22
5.
EL1.1U
action holder: MIPS
action holder: St-by
autonomous action
Service Modes, Error Codes, and Fault Finding
26" /32" / 37" / 42" LCD LPL
Semi Standby
Wait until previous on-state is left more than 2
seconds ago. (to prevent LCD display problems)
Assert RGB video blanking
and audio mute
Initialize audio and video processing ICs and
functions according needed use case.
Wait until QVCP generates a valid LVDS output
Switch "on" 12V LCD supply
(LCD-Power-on)
Start to apply valid interface signals to the module (LVDS) within a time
frame of min. 17.5ms to max. 67.5ms after supply switch "on".
In implementation, use 25ms, this makes it compatible with 37HD"Sharp
(t=17.5ms is the supply switch-on delay taken into account)
Wait 250ms (min. = 200ms)
Switch "off" RGB blanking
Switch "on" LCD lamp after valid, stable video, corresponding
to the requested output is delivered by the Viper
Switch Audio-Reset and sound enable "low" and demute
Active
Figure 5-6 "Semi Stand-by" to "Active" flowchart
clock.
G_16290_079.,eps
020206