EN 18
5.
EL1.1U
"CHANNELS", "MOVIE RATINGS LOCK". Possible values
are: "ALL", "NR", "G", "PG", "PG-13", "R", "NC-17" and "X".
V-Chip Tv Status. Indicates the setting of the V-chip as
applied by the selected TV channel. Same values can be
shown as for "TV RATINGS LOCK".
V-Chip Movie Status. Indicates the setting of the V-chip
as applied by the selected TV channel. Same values can
be shown as for "MOVIE RATINGS LOCK".
Options 1. Gives the option codes of option group 1 as set
in SAM (Service Alignment Mode).
Options 2. Gives the option codes of option group 2 as set
in SAM (Service Alignment Mode).
AVL. Indicates the last status of AVL (Automatic Volume
Level): "ON" or "OFF". Change via "MENU", "TV",
"SOUND", "AVL". AVL can not be set in case of digital
audio reception (e.g. Dolby Digital or AC3)
Delta Volume. Indicates the last status of the delta volume
for the selected preset as set by the customer: from "-12"
to "+12". Change via "MENU", "TV", "SOUND", "DELTA
VOLUME".
HDMI key validity. Indicates the key's validity.
IEEE key validity. Indicates the key's validity (n.a.).
POD key validity. Indicates the key's validity (n.a.).
Digital Signal Quality. Indicates quality of the received
digital signal (0= low).
How to Exit CSM
Press any key on the RC-transmitter (with exception of the
"CHANNEL +/-", "VOLUME", "MUTE" and digit (0-9) keys).
Service Modes, Error Codes, and Fault Finding
Mains
"off"
- WakeUp requested
- Acquisition needed
Stand-by
(Off St-by)
- No data Acquisition required
and no POD present
- Tact SW pushed
- WakeUp requested
- Acquisition needed
- POD Card remove
d
- Tact SW pushed
POD
Stand-by
On
*
TM
Only applicable for sets with CableCARD
slot (POD)
Figure 5-2 Transition diagram
5.3
Stepwise Start-up
The stepwise start-up method, as known from FTL/FTP sets is
not valid any more. The situation for this chassis is as follows:
when the TV is in a protection state detected via the Stand-by
Processor (and thus blinking an error) and SDM is activated via
shortcutting the pins on the SSB, the TV starts up until it
reaches the situation just before protection. So, this is a kind of
automatic stepwise start-up. In combination with the start-up
diagrams below, you can see which supplies are present at a
certain moment.
Important to know here is, that if e.g. the 3V3 detection fails
(and thus error 11 is blinking) and the TV is restarted via SDM,
the Stand-by Processor will enable the 3V3, but will not go to
protection now. The TV will stay in this situation until it is reset
(Mains/AC Power supply interrupted).
The abbreviations "SP" and "MP" in the figures stand for:
SP: protection or error detected by the Stand-by
Processor.
MP: protection or error detected by the VIPER Main
Processor.
Off
Mains
"on"
WakeUp
requested
Semi
Stand-by
- St-by requested
- Tact SW pushed
No data Acquisition
WakeUp
required and
requested
POD present
GoToProtection
*
GoToProtec
tion
Protection
Active
GoToProtection
F_15400_095.eps
020206