Mechanical safety
Mechanical safety
Flown congurations
The Kiva II rigging system complies with 2006/42/EC: Machinery Directive. It has been designed following the
guidelines of BGV-C1.
2006/42/EC: Machinery Directive species a safety factor of 4 against the rupture. The own deployments described in
this manual achieve a safety factor of 4 or higher.
Refer to Soundvision for the safety factor of a specic deployment.
The safe limit gives the maximum number of elements for which the safety factor is always compliant with the
2006/42/EC: Machinery Directive, regardless of the other deployment parameters (site angles, inter-enclosure angles,
etc.)
The maximum limit gives the maximum number of elements for which the safety factor can be compliant with the
2006/42/EC: Machinery Directive, when the other deployment parameters provide the best mechanical conditions.
For mixed arrays refer to your Soundvision model.
Kiva II
Conguration
Rigging accessory
Flown
KIBU-SB
Flown
KIBU II
Pullback
KIBU II / KIBU-SB + KIVA-PULLBACK
Ceiling-mounted
KIET II
SB15m
Conguration
Rigging accessory
Flown
KIBU-SB
Kiva II + SB15m
Conguration
Rigging accessory
Pullback
KIBU-SB + KIVA-PULLBACK
Other congurations
For other congurations, respect the recommended maximum limit for optimal stability.
Kiva II
Conguration
Rigging accessory
Stacked
KIBU-SB
Pole-mounted
KIET II + 35 mm pole
Pole-mounted
KIET II + 35 mm pole + SB15m
SB15m
Conguration
Ground-stacked
Mechanical safety of the rigging system
Before any installation, always model the system in Soundvision and check the Mechanical Data section for
any stress warning or stability warning.
Kiva II rigging manual (EN) version 2.0
Rigging accessory
No rigging accessory
Safe limit
Maximum limit
12
12
9
3
Maximum / Safe limit
8
Maximum / Safe limit
9 Kiva II + 3 SB15m
Safe limit
Maximum limit
4
3
2
Maximum / Safe limit
4
20
20
9
8