The counter counts the number of edges on the Source input while the Gate input remains active.
On each sample clock edge, the counter stores the count in the FIFO of the last pulse width to
complete. The STC3 transfers the sampled values to host memory using a high-speed data
stream.
Figure 5-7 shows an example of a sample clocked buffered pulse-width measurement.
Figure 5-7. Sample Clocked Buffered Pulse-Width Measurement
Pulse
Source
Sample Clock
Buffer
If a pulse does not occur between sample clocks, an overrun error occurs.
Note
For information about connecting counter signals, refer to the
section.

Pulse Measurement

In pulse measurements, the counter measures the high and low time of a pulse on its Gate input
signal after the counter is armed. A pulse is defined in terms of its high and low time, high and
low ticks or frequency and duty cycle. This is similar to the pulse-width measurement, except
that the inactive pulse is measured as well.
You can route an internal or external periodic clock signal (with a known period) to the Source
input of the counter. The counter counts the number of rising (or falling) edges occurring on the
Source input between two edges of the Gate signal.
You can calculate the high and low time of the Gate input by multiplying the period of the Source
signal by the number of edges returned by the counter.
Refer to the following sections for more information about cDAQ chassis pulse measurement
options:
Single Pulse Measurement
Implicit Buffered Pulse Measurement
Sample Clocked Buffered Pulse Measurement
2
2
NI cDAQ-9181/9184/9188/9191 User Manual
4
2
4
Default Counter/Timer Routing
© National Instruments | 5-7