Mmaw (Stick) Welding; Mma Welding - Weldtronic TTIG200PADP Operating Manual

Titantig 200p ac/dc pro tig/stick welder
Table of Contents

Advertisement

3.1 MMAW (Stick/MMA) Welding
Location
The machine should be located in a suitable position and environment. Care should be taken to
avoid moisture, dust, steam, oil or corrosive gases
Place on a secure level surface and ensure that there is adequate clearance around the machine
to ensure natural airflow.
Input connection
Before connecting the machine you should ensure that the correct supply is available. Details of
the machine requirements can be found on the data plate of the machine or in the technical
parameters shown in the manual.
The equipment should be connected by
a suitably qualified competent person.
Always ensure the equipment has a
proper grounding.
Never connect the machine to the mains
supply with the panels removed.
Output connections
Electrode polarity
In general when using manual arc
welding electrodes the electrode holder
is connected the positive (+) terminal
and the work return to the negative
terminal. Always consult the electrode
manufacturer's data sheet if you have
any doubts.
When using the machine for TIG welding
the TIG torch should be connected to the
negative terminal and the work return to
the positive terminal

MMA Welding

Insert the cable plug with electrode
holder into the "+" socket on the front
panel of the welding machine, and
tighten it clockwise.
Insert the cable plug of the work return
lead into the "-" socket on the front
panel of the w e l d i n g machine, and tighten it clockwise
After connecting the welding leads as detailed you will need to switch the power switch on the
back panel to "ON"
TitanTig 200P ACDC Pro Operators Manual Issue. A 0516

Advertisement

Table of Contents
loading

Table of Contents