L o w e r L e g R e m o v a l a n d S e r v i c e
5 0 / 2 0 0 H o u r S e r v i c e
Remove the air valve cap.
1
Depress the Schrader valve and release all air pressure.
2
⚠ CAU TION - E YE HAZARD
Verify all pressure is removed from the fork before proceeding. Failure
to do so can result in injury and/or damage to the fork. Wear safety
glasses.
Turn the rebound adjuster knob counter-clockwise until it stops. This is
3
the full open/fast rebound setting.
Loosen the rebound adjuster knob screw and remove the rebound
adjuster knob.
L o w e r L e g R e m o v a l
DebonAir™
DebonAir
2.5 mm
Lower Leg Removal and Service
Dual Position Air™
Dual Position Air
12