Briefly pressing the measuring button 2 [
ous measurement. The current measured value will be shown at the bot-
1.291
m
min
tom of the display. The maximum and minimum measured value appear
-64°
11.623
m
max
above it. Pressing the measuring button 2 [
11.623 m
continuous measurement.
Continuous measurement automatically switches off after 5 mins.

Area Measurement

Select the area measurement

Then measure the width and length one after the other as with a length measurement.
The laser beam remains switched on between the two measurements. The distance
to be measured flashes in the indicator for area measurement
The first measured value is shown at the top of the display.
After the second measurement has been completed, the area will be au-
tomatically calculated and displayed. The end result is shown at the bot-
0.0°
3.810
m
5.080 m
tom of the display, while the individual measured values are shown
19.355 m
2
above it.

Volume Measurement

Select the volume measurement
Then measure the width, length and depth one after the other as with a length meas-
urement. The laser beam remains switched on between the three measurements. The
distance to be measured flashes in the indicator for volume measurement
The first measured value is shown at the top of the display.
After the third measurement has been completed, the volume will be
10.160
m
automatically calculated and displayed. The end result is shown at the
0.0°
11.430
m
12.700 m
bottom of the display, while the individual measured values are shown
1474.8 m
3
above it.

Indirect Distance Measurement

For indirect length measurements, three measuring modes are available. Each meas-
uring mode can be used for determining different distances.
The indirect distance measurement is used to measure distances that cannot be
measured directly because an obstacle would obstruct the laser beam or no target
surface is available as a reflector. This measuring procedure can only be used in ver-
tical direction. Any deviation in horizontal direction leads to measuring errors.
Bosch Power Tools
.
.
English | 17
], interrupts the continu-
] once more, restarts the
.
1 609 92A 3UB | (15.3.17)
.

Hide quick links:

Advertisement

Table of Contents