100
Motor type
Random-wound ABB
M2__, M3__ motors
Form-wound ABB HX_ or
modular motor
manufactured before
1 Jan 1998
Random-wound ABB HX_
and AM_ motor
manufactured before
1 Jan 1998
Random-wound ABB HX_
and AM_ motor
manufactured from
1 Jan 1998
Other ABB motors, or
random-wound or form-
wound non-ABB motors
du/dt filters are optional accessories and to be ordered separately. For more
information on common mode filtering, contact your local ABB representative.
Contact the motor manufacturer for information on the motor construction.

Filter types

du/dt filters

Drive type
ACS850-04...
du/dt and common mode filtering
Supply voltage
insulation
(U
)
N
system
U
< 500 V
N
U
< 500 V
N
Enamelled wire
U
< 500 V
with fiberglass
N
Enamelled wire
U
< 500 V
with fiberglass
N
Standard
U
< 420 V
N
LL
Standard
LL
420 V < U
<
Reinforced
N
500 V
LL
0.2 microsecond
rise time)
du/dt filters for ACS850-04
-03A0-5
-03A6-5
-04A8-5
-06A0-5
NOCH0016-60 (3-phase)
-08A0-5
-010A-5
-014A-5
-018A-5
-025A-5
-030A-5
NOCH0030-60 (3-phase)
-035A-5
-044A-5
-050A-5
NOCH0070-60 (3-phase)
-061A-5
-078A-5
NOCH0120-60 (1-phase; three
-094A-5
filters included in kit)
Motor
du/dt filtering
Any
Check with motor
Any
manufacturer
taping
taping
= 1300 V)
Yes
= 1300 V)
= 1600 V,
Filter type
Requirement
Insulated N-end
bearing
Yes
Check with motor manufacturer
Yes
Common mode
filtering
Yes
Yes