3
Reset
The fitting is put back into installation mode.
Beware
Access by unauthorised persons is possible! There is a security leak.
Program the Master-Code at once.
If you leave the fitting in the original installation mode, it can be activated with pressing 0 (zero).
If you reset the system:
all User-Codes are cancelled.
the Master-Code is 0 (zero).
the security fitting is activated.
Reset
Dismantle the interior fitting. You will find a detailed description from
the assembly instructions for the fitting.
The flat ribbon cable must be activated.
All batteries must be inserted and functional.
Press the reset tester and hold down for 4 – 6 seconds
(not longer!).
After let go the reset tester, the fitting should deactivate and the green
LED (
) should flash several times.
Assemble the fitting. You will find a detailed description from the
assembly instructions for the fitting.
Remark:
Shall the fitting doesn´t react despite of several attempts
with variat
then:
Remove batte
ries.
Wake up Anykey se
Put batteries back in.
Repeat that procedure.
Assemble the fitting.
D00422
02
ion of the time window (4 to 6 seconds),
curity fitting (Hold the chip card in front of the reading module).
R e s e t
Seite 45