Summary of Contents for Assa Abloy Aperio

  • Page 1 Install Guide Assa Abloy Aperio Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 All specifications are subject to change without notice sales@verkada.com Copyright © Verkada Inc. All rights reserved.
  • Page 2: Document Details

    Document Document Details V1.0 (20211008) (V1.0 first published 20230523) Firmware Firmware version can be verified on Verkada Command command.verkada.com. Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 All specifications are subject to change without notice sales@verkada.com Copyright © Verkada Inc. All rights reserved.
  • Page 3 Background Assa Abloy’s Aperio technology is a cross brand wireless communication protocol centered around their AH series hub. Please contact your Assa Abloy representative to find out which wireless lock under the Aperio umbrella works for your use case. Verkada specifically integrates with the AH30 hub which communicates with the AC41/AC42 via the RS-485 module in the AUX cassette/terminal block.
  • Page 4: Common Use Cases

    These verticals use wireless locks because they do not require expensive wiring to be run through walls and allow much more flexibility. They are also much more cost effective than wired doors. This integration allows us to work with existing customers with Aperio enabled wireless locks.
  • Page 5 This step is done first simply to provide power to the AH30. No Command configuration is required until after the locks and hub are successfully connected. Post Aperio Lock setup Once you have successfully linked your locks to your hub, you will need to write down all the EAC addresses.
  • Page 6: Command Configuration

    Command Configuration Add the AC41/42 to Command and select Assa Abloy Once the AC41/AC42 is added and in Assa Abloy mode, navigate to the controller and click add door. The window to the right will pop up. Select the type...
  • Page 7 Installation Command Configuration Cont. A successful connection will result in on “online” status for the lock. The settings page of the AC41/AC42 will also signal the health of the connection. Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 All specifications are subject to change without notice sales@verkada.com Copyright ©...
  • Page 8 ↔ Troubleshooting Guidelines Verify that your ACU is in schlage mode - if you forgot to set it to Assa Abloy mode, you will need to decommission it and re-add it. Verify that the Assa Abloy Locks and AH30ss have been successfully paired Ensure that the addresses for each Assa Abloy lock were successfully configured.
  • Page 9 Appendix Support Thank you for purchasing this Verkada product. If for any reason things don’t work right, or you need assistance, please contact us immediately. verkada.com/support Sincerely, The Verkada Team Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 All specifications are subject to change without notice sales@verkada.com Copyright ©...