4.5 TECHNICAL PARAMETERS FOR COMBINATION BOILERS (IN COMPLIANCE WITH
REGULATION 813/2013)
Model/s:
Condensing Boilers:
Low temperature boiler:
Boiler type B1:
Co-generation appliance for central heating:
Mixed heating appliance:
Element
Nominal heat output
For central heating only and combination boilers: useful heat output
At nominal heat output in high temperature
mode (*)
At 30% of nominal heat output in a low
temperature mode (**)
Auxiliary electricity consumption
At full load
At partial load
In standby mode
For mixed central heating appliances
Stated load profile
Daily electrical power consumption
Contact information
(*) High temperature mode means 60°C on return and 80°C on flow.
(**) Low temperature mode for condensation Boilers means 30°C , for low temperature boilers 37°C and for other appliances 50°C of return
temperature.
The efficiencies and NO
values in the following tables refer to the gross calorific value.
x
VICTRIX OMNIA
SI
NO
NO
NO
Fitted with supplementary heating system:
SI
Symbol
Value
Unit
Element
P
20
kW
Seasonal energy efficiency of central heating
n
For central heating only and combination boilers: useful efficiency
At nominal heat output in high temperature
P
20,2
kW
mode (*)
4
At 30% of nominal heat output in a low
P
6,6
kW
temperature mode (**)
1
Other items
el
0,018
kW
Heat loss in standby
max
el
0,011
kW
Ignition burner energy consumption
min
P
0,004
kW
Emissions of nitrogen oxides
SB
XL
Domestic hot water production efficiency
Q
0,138
kWh Daily gas consumption
elec
IMMERGAS S.p.A. VIA CISA LIGURE, 95 - 42041 BRESCELLO (RE) ITALY
NO
Symbol
Value
Unit
η
91
%
S
η
87,3
%
4
η
95,8
%
1
P
0,055
kW
stby
P
0,000
kW
ign
mg/
NO
32
kWh
x
η
82
%
WH
Q
23,932
kWh
fuel
87