Wall-hung, room sealed boilers with storage tank (31 pages)
Summary of Contents for Immergas VICTRIX ZEUS 26 2 ERP
Page 1
VICTRIX ZEUS Instruction and recommendation booklet 26 2 ErP...
Page 3
Read the following pages carefully: you will be able to draw useful suggestions regarding the correct use of the appliance, the respect of which, will confirm your satisfaction for the Immergas product.
(e.g. the Authorised Tech- RECOMMENDATIONS. nical Assistance centre, which has specifically The Victrix Zeus 26 2 ErP boiler has been de- trained staff and original spare parts). Do not signed for wall mounted installation only; for attempt to modify or repair the appliance alone.
- the essential components of the boiler and/or solution must be made with potential pollution antifreeze kit are not faulty. class of water 2 (EN 1717:2002). The materials used for the central heating circuit of Immergas boilers withstand ethylene and...
Ensure correct gas cock connection. The gas sup- , this network must also have a multi-pole cir- ply pipe must be suitably dimensioned according Attention: Immergas declines all liability in the cuit breaker with class III over-voltage category. to current regulations in order to guarantee cor-...
(Fig. 1-4). tion sheet for positioning of the external probe. with its climate thermostat function disabled, i.e. All Immergas chrono-thermostats are connected The probe can be connected directly to the boiler it must be set to On/Off mode.
• N.B.: for safety purposes, do not obstruct the Attention: the boiler must be installed ex- boiler intake/exhaust terminal, even temporar- clusively with an original Immergas “Green ily. Range” inspectionable air intake device and fumes extraction system made of plastic, as •...
Page 10
Resistance Equivalent length Equivalent Equivalent length Equivalent length TYPE OF DUCT Factor in m of concentric length in metres in metres of pipe in m of concentric pipe Ø 60/100 of pipe Ø 80 Ø 60 pipe Ø 80/125 Intake m 7.3 Concentric pipe Ø...
- the fumes exhaust must be connected to its own single flue (B23) or ducted directly outside via a vertical terminal for direct exhaust (B ) or via an Immergas ducting system (B The technical regulations in force must be respected. • Coverage kit assembly (Fig. 1-9). Remove the cap and gasket from the intake hole.
Make sure that the external silicone wall concentric bend leaving the boiler. If addi- Immergas also provides a Ø 60/100 simplified sealing plate is properly inserted in the wall. tional components are assembled, the length...
1.13 CONCENTRIC VERTICAL KIT male side (5) (smooth) into the flange (2) up to Position the fixed half-shell (5) on the aluminium INSTALLATION. the end stop; making sure that the wall sealing tile and insert the intake-exhaust pipe (7). Fit the Type C configuration, sealed chamber and plate has been fitted (3), this will ensure sealing Ø...
1.14 SEPARATOR KIT INSTALLATION. side (smooth) to the female side of the bend Type C configuration, sealed chamber and (5) up to the end stop; making sure that the fan assisted. internal wall sealing plate has been fitted, this will ensure sealing and joining of the elements Separator kit Ø...
N.B.: (version Ø 125 only) before assembly - The maximum vertical extension using a Ø 80 This kit allows an Immergas boiler to be installed check the gaskets are in the right position. In ducting system is 28 m, the maximum exten- in "C...
1.17 CONFIGURATION TYPE B, OPEN more than 30% less with respect to the maximum Immergas ducting system. The Ø 60 rigid and Ø CHAMBER AND FAN ASSISTED FOR that can be attached and powered by the same 80 flexible “Green Range”...
Tighten the cap after the operation. 1.24 DOMESTIC HOT WATER STORAGE TANK UNIT. The Victrix Zeus 26 2 ErP storage tank unit has 1.21 CONDENSATE TRAP FILLING. a capacity of 45 litres. It contains a large coiled On first lighting of the boiler, flue gas may come stainless steel heat exchanger pipe, which allows out the condensate drain;...
1.26 CIRCULATION PUMP. 1-26 The boiler is supplied with circulator fitted with speed regulator. These settings are suitable for most systems. In fact, the pump is equipped with electronic control to set advanced functions. For proper op- Key: eration one must select the most suitable type of 1 - Function selection button operation for the system and select a speed in the 2 - Green (G) / red (R) LED...
Page 19
Head available to the system. 1-28 Key: Vn = Available head An = Circulating pump absorbed power Flow rate (l/h)
Immergas warranty. We recommend stipulating a yearly cleaning and maintenance contract with - never pull electrical cables nor leave the ap- an authorised local firm.
2.5 TROUBLESHOOTING. Remoto control connected, the boiler selector tor switch (4) is used to regulate the radiator The Victrix Zeus 26 2 ErP boiler signals any switches (3) and (4) are excluded. The ( temperature, while selector (3) continues be- anomalies using a code shown on the boiler symbol is displayed.
2.10 ANTI-FREEZE PROTECTION. 2.12 DECOMMISSIONING. N.B.: close the cock after the operation. The “Victrix Zeus 26 2 ErP” series boiler has an In the event of permanent shutdown of the boiler, anti-freeze function that switches the burner If pressure values reach around 3 bar the safety contact professional staff for the procedures and valve may be activated.
BOILER COMMISSIONING - switch the boiler on and check correct ignition; - check the production of domestic hot water; (INITIAL CHECK) - check the ∆p gas values in domestic hot water - check sealing efficiency of water circuits; and central heating modes; - check ventilation and/or aeration of the instal- To commission the boiler: - check the CO...
3.2 WIRING DIAGRAM. BK - Black BL - Blue BR - Brown G - Green GY - Grey G/Y - Green-Yellow OR - Orange P - Purple PK - Pink R - Red W - White Y - Yellow Key: M20 - Fan 1 - Anti-freeze kit A4 - Display board...
3.4 CONVERTING THE BOILER TO Key: SIT 848 Gas Valve OTHER TYPES OF GAS. 1 - Gas valve inlet pressure point If the boiler has to be converted to a different 2 - Gas valve outlet pressure point gas type to that specified on the data nameplate, 3 - Off/Set adjustment screw request the relative conversion kit for quick and 12 - Outlet gas flow rate regulator...
fectly closed and there are no leaks from the 3.8 CHECKS FOLLOWING 3.13 PUMP ANTI-LOCK FUNCTION. CONVERSION TO ANOTHER TYPE gas circuit; During the "Summer" phase the boiler has a func- OF GAS. tion that starts the pump at least once every 24 - seal the gas flow rate regulation devices (if set- After making sure that conversion was carried hours for the duration of 30 seconds in order to...
3.18 YEARLY APPLIANCE CHECK AND - Check integrity of the storage tank Magnesium MAINTENANCE. anode. The following checks and maintenance should - Check the condition and integrity of the electri- be performed at least once a year. cal system and in particular: - Clean the flue side of the heat exchanger.
3.19 CASING REMOVAL. Unhook the lower part of the casing as described To facilitate boiler maintenance the casing can in the figure. be completely removed by following these simple - Pull the casing towards you and up at the same instructions (Fig.
3.20 VARIABLE HEAT OUTPUT. of a mm or Pascal. The power data in the table N.B.: the pressures indicated in the table repre- has been obtained with an intake-exhaust pipe sent the differences of pressures at the ends of measuring 0.5 m in length. Gas flow rates refer the Venturi mixer and can be measured from the to the lower calorific value at a temperature of pressure points in the upper part of the sealed...
3.23 KEY FOR DATA PLATE. Cod. Md Sr N° Cod. PIN Type n min. max. n min. n max. Class CONDENSING N.B.: the technical data is provided on the data plate on the boiler Model Cod. Md Model code Sr N° Serial Number Check Cod.
Contact information IMMERGAS S.p.A. VIA CISA LIGURE, 95 - 42041 BRESCELLO (RE) ITALY (*) High temperature mode means 60°C on return and 80°C on flow. (**) Low temperature mode for condensation Boilers means 30°C , for low temperature boilers 37°C and for other appliances 50°C of return tempera- ture.
Use sheet fig. 3-8 for “assemblies” related to In case you should wish to install an assembly, the heating function (e.g.: boiler + temperature starting from the Victrix Zeus 26 2 ErP boiler, use controller). the assembly charts in fig. 3-8 and 3-11.
Page 35
Parameters for filling in assembly chart. Parameter Victrix Zeus 26 2 ErP ‘I’ ‘II’ ‘III’ 1.11 ‘IV’ 0.44 * to be established by means of table 5 of Regulation 811/2013 in case of “assembly” including a heat pump to integrate the boiler. In this case the boiler must be considered as the main appliance of the assembly.
Page 36
Facsimile for filling in domestic hot water production system assembly chart. Water heating energy efficiency of mixed boiler ‘I’ Stated load profile: Solar contribution From the board of the solar device Auxiliary electricity ( 1,1 ‘I’ 10 % ) ‘II’ ‘III’...
Page 37
Parameters for filling in DHW package assembly chart. Parameter Victrix Zeus 26 2 ErP ‘I’ ‘II’ ‘III’ * to be determined according to Regulation 811/2014 and transient calculation methods as per Notice of the European Community no. 207/2014. 3-10 Domestic hot water production system assembly chart.
Page 40
Follow us Immergas Italia immergas.com Immergas S.p.A. 42041 Brescello (RE) - Italy Tel. 0522.689011 Fax 0522.680617 Certified company ISO 9001 ИЗКЛЮЧИТЕЛЕН ПРЕДСТАВИТЕЛ И СЕРВИЗ АМАКС ГАЗ ООД 1261 Мрамор, София ул В. Левски 148 Tel. 0700 112 66 Fax 02 902 46 70...
Need help?
Do you have a question about the VICTRIX ZEUS 26 2 ERP and is the answer not in the manual?
Questions and answers