Configuring Timing References - Alcatel-Lucent 7210 SAS M Configuration Manual

Service access switch
Hide thumbs Also See for Alcatel-Lucent 7210 SAS M:
Table of Contents

Advertisement

Configuring Timing References

Listed below is an example to configure timing reference parameters.
Example:
The following displays the timing reference parameters:
7210 SAS M, T, X, R6 Basic System Configuration Guide
config>system# sync-if-timing
config>system>sync-if-timing# begin
config>system>sync-if-timing# ref1
config>system>sync-if-timing>ref1# source-port 1/1/1
config>system>sync-if-timing>ref1# no shutdown
config>system>sync-if-timing>ref1# exit
config>system>sync-if-timing# ref2
config>system>sync-if-timing>ref2# source-port 1/1/2
config>system>sync-if-timing>ref2# no shutdown
config>system>sync-if-timing>ref2# exit
config>system>sync-if-timing>commit
*7210-SAS>config>system>sync-if-timing#info detail
----------------------------------------------
ref-order ref1 ref2
ref1
source-port 1/1/1
no shutdown
exit
ref2
source-port 1/1/2
no shutdown
exit
no revert
----------------------------------------------
System Management
Page 303

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Alcatel-lucent 7210 sas tAlcatel-lucent 7210 sas r6 osAlcatel-lucent 7210 sas x

Table of Contents