Serial Number Plate; Adjustments - Beretta METEO GREEN HE R.S.I. Installer And User Manual

Table of Contents

Advertisement

21 - SERIAL NUMBER PLATE

Q
nominal capacity
P
nominal power
IP
protection level
t max
temperature
NOx
NOx value class
METEO GREEN HE R.S.I.
Serial No.
Condensing Boiler
IAPMO Certificate No. GMK10203
max min
Q
kW
P 80°-60°
kW
P 50°-30°
kW
max water pressure
min water pressure
t max
max gas pressure
MJ/h NG
MJ/h ULPG
min inlet pressure NG
min inlet pressure ULPG
CO
limits (all models):
2
230 V ~ 50 Hz
IPX5D NOx:
Safety valve setting =
Weight (net) =

22 - ADJUSTMENTS

The boiler has already been factory adjusted by the manufacturer. If a new
adjustment is required, for example, after extraordinary maintenance, replac-
ing the gas valve or converting fro m natural gas to LPG, proceed as follows.
Maximum and minimum power, minimum and maximum heating,
must be adjusted in the indicated sequence by qualified staff.
- Unscrew the lower cover fixing screw (A-B) (Fig. 1.5).
- Pull the cover towards you and remove.
- Lift up the panel and turn it forwards
CALIBRATION & SERVICE operations must be performed with the
boiler in the OFF position. To do this, press the
shows "- -" (Fig. FF).
PAR.
MEANING
1
Kind of gas- don't change
2
Power boiler
3
Thermal insolation of the house
ONLY IF IS CONNECTED THE EXTERNAL SENSOR
10
Tipe of sanitary DHW
45
CH1 OTC (climatic curve)
ONLY IF IS CONNECTED THE EXTERNAL SENSOR
EAN 80-18000-32117-1
Appliance category:
button until the display
Parameter with password 18
CH1 = first CH circuit / CH2 = second CH circuit
During parameter modification operations, the "select functions" button
acts as an ENTER (confirm) button, the
button. If no confirmation is given within 10 seconds, the value is dis-
carded and returns to the previously set one.
SETTING THE PASSWORD
To enter the password, and then setting the parameters, follow the procedure:
1.
Turn the boiler in OFF, press the ON / OFF button until the display shows
two horizontal lines "--".
2.
Simultaneously press the button INFO and MODE 5" until the display
shows:
In display 4 digits written intermittent "Code" - "0000".
In display 2 digit visualized 00.
Press MODE to confirm and to enter their passwords by turning the encoder
DHW, and then always confirm the code by pressing another time MODE.
In the display 2-digit appears the number of the parameter, in the display
4-digit appears the value.
CALIBRATION PHASES
In this boiler we have the possibility of three different mode for three differ-
ent level of setting:
Level one Programmer Setting
Use password 53
With this mode is possible change all the parameter. This mode is useful for
personalize the boiler in function of the type of installation.
Level two Adjusting Setting (Calibration end Setting)
Use password 18
With this mode is possible change ONLY the parameter for setting the boiler.
E.g. this mode is useful when you need to change the gas.
Level three Combustion Analysis mode
Use password 19 (RANGE RATED & chimney sweeper function)
With this mode is possible do set up the maximum power in heating and
make the combustion analysis test at this power.
UNIT
MIN
--
1 = G20 - LPG
--
26 = (25 kW)
34 = (35 kW)
min
5
--
0 =OFF
1 =Istant
2 =not used
3= Ext. Tank with
thermostat
4= Ext. Tank with NTC
sensor
5= not used
--
2,5
METEO GREEN HE R.S.I.
button acts as an ESCAPE
MAX
STEP
DEFAULT
1
1
26-30
26-34
20
1
5
1
1
40
2,5
20
(continued)
27