Rx Test Specification - Alinco DR-135 Service Manual

Hide thumbs Also See for DR-135:
Table of Contents

Advertisement

4) Rx Test Specification

TEST ITEM
RX Sensitivity
RX Distortion
RX S/N
Squelch
Sensitivity
S Meter
AF Output
CTCSS Sensitivity
DCS Sensitivity
Drain Current
Power Off Current 440 05MHz
Howling
CONDITION
ADJ STANDARD TEST STANDARD
350.05MHz
Less than -1dBu
430.05MHz
Less than -7.5dBu
440.05MHz
Less than -7.5dBu
450.05MHz
Less than -7.5dBu
511.95MHz
Less than +1dBu
440.05MHz
Less than -7.5dBu Less than -6.5dBu
NARROW
WIDE
Less than 4%
NARROW
WIDE
More than 40dB
NARROW
More than 34dB
440.05MHz
Squelch Open
Indication 02
Squelch Close
440.05MHz
All appears at
1KHz
20dBu
3.5KHz/DEV
440 05MHz
More than 2W
Open at
WIDE
500Hz/DEV
NARROW
Open at
250Hz/DEV
WIDE
Opens when Test
Equipment is in Tx
NARROW
Opens when Test
Equipment is in Tx
440 05MHz
Less than 0 7A
Less than 10mA
440.05MHz
Don't occur
NARROW
MODE
Less than 0dBu
12dBSINAD
Less than -6.5dBu
Less than -6.5dBu
Less than -6.5dBu
Less than +2dBu
Less than 5%
SSG Output 40dBu
More than 38dB
SSG Output 40dBu
0.3~3KHzBPF OFF
More than 32dB
Squelch Open
SSG Output -10dBu
Squelch Close
SSG Output OFF
All appears at
Decrease SSG level and
25dBu
decrease S Meter level
More than 2W
SSG Output 40dBu
Open at
SSG Output 0dBu
500Hz/DEV
88.5Hz
Open at
250Hz/DEV
Opens when Test
255 code
Equipment is in Tx
Opens when Test
255 code
Equipment is in Tx
Less than 0 7A
MAX VR
Less than 10mA
Power Off
Don't occur
SSG Output 60dBu
MOD OFF MAX VR
NOTE
47

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dr-435mkii

Table of Contents