2) VCO and RX Adjustment Specification

ITEM
Adjustment
145.90MHz
Frequency
TX
VCO
136.00MHz
Adjustment
RX
VCO
173.99MHz
Confirmation
RX
Rx Signal
146.05MHz
Sensitivity
Adjustment
136.05MHz
146.05MHz
173.95MHz
Squelch
146.05MHz
Adjustment
SSG OFF
Indication 01
S Meter
146.05MHz
Adjustment
SSG20dBu 1KHz
3.5KHz/DEV

3) Tx Adjustment Specification

ITEM
HI POWER
146.00MHz
Adjustment
HI POWER
MID POWER
146.00MHz
Adjustment
MID POWER
LOW POWER
146.00MHz
Confirmation
LOW POWER
Maximum
146.00MHz
Deviation
MOD
Adjustment
1KHz40mVemf
WIDE
Maximum
146.00MHz
Deviation
MOD
Adjustment
1KHz40mVemf
NARROW
Mic Gain
146.00MHz
Adjustment
MOD
1KHz4mVemf
WIDE
CTCSS
146.00MHz
Modulation
88.5Hz
Level
Confirmation
DCS
146.00MHz
Modulation
255 Code
Level
Adjustment
1750Hz
146.00MHz
Modulation
1750Hz
Level
Confirmation
DTMF
146.00MHz
Modulation
DTMF
Level
Press the V/M
Confirmation
key during TX
UNIT
CONDITION
MAIN VR109
MAIN
MAIN
MAIN
MAIN
MAIN
UNIT
CONDITION
MAIN
MAIN
MAIN
MAIN
MAIN
MAIN
MAIN
MAIN
MAIN
MAIN
1
ADJ.SPOT
ADJUSTING METHOD
Adjust so that Tx Frequency
becomes within 145.90MHz±100Hz
L123
Adjust so that PD voltage becomes
1.5V
Confirm if PD voltage becomes less
than 7.3 V
L105, L104
Repeatedly adjust so that the Rx
L103, L102
sensitivity becomes in maximum.
Confirm:
At -7dBu SINAD more than 12dB
At -8dBu SINAD more than 12dB
At -6dBu SINAD more than 12dB
VR101
Adjust so that the squelch stops at
perfectly close location
VR102
Adjust so that all the indicator
appears
ADJ.SPOT
ADJUSTING METHOD
VR103
Adjust to 50.0±1.0W
VR104
Adjust to 10.0±1.0W
Confirm if it becomes 4.0 ±1.0W
VR107
4.5±0.1KHz/DEV
VR105
2.2±0.1KHz/DEV
VR106
3.0±0.1KHz/DEV
800±200Hz/DEV 3KHz LPF ON
VR108
800±50Hz/DEV 3KHz LPF ON
3.0±0.5KHz/DEV
3.0 ±0.5KHz/DEV