Varian CP4900 User Manual

Varian CP4900 User Manual

Micro-gc extension box
Hide thumbs Also See for CP4900:

Advertisement

Quick Links

CP-4900 Micro-GC
Extension Box
North/South America
2700 Mitchell Drive
Walnut Creek
94598 California, USA
Tel: ++(1)9259392400
Fax: ++(1)9259452360 or
++(1)9259452344
© 2004 Varian BV. All Rights Reserved
User Manual
Europe
P.O. Box 8033
4330 EA Middelburg
The Netherlands
Tel: ++(31)118671000
Fax: ++(31)118623193
Printed in the Netherlands
Varian B.V.
Herculesweg 8
4330 EA Middelburg
The Netherlands
Australia/East Asia
679 Springvale Road
Mulgrave, Victoria 3171
Australia
Tel: ++(61)395607133
Fax: ++(61)395607950
CP501369 Rev:1 June 2004

Advertisement

Table of Contents
loading

Summary of Contents for Varian CP4900

  • Page 1 4330 EA Middelburg Mulgrave, Victoria 3171 94598 California, USA The Netherlands Australia Tel: ++(1)9259392400 Tel: ++(31)118671000 Tel: ++(61)395607133 Fax: ++(1)9259452360 or Fax: ++(31)118623193 Fax: ++(61)395607950 ++(1)9259452344 © 2004 Varian BV. All Rights Reserved Printed in the Netherlands CP501369 Rev:1 June 2004...
  • Page 2: Varian Analytical Instrument Warranty

    Support Representative to the site or by authorizing the Customer to return the defective accessory or instrument to Varian or to send it to a designated service facility. The Customer shall be responsible for loss or damage in transit and shall prepay shipping cost.
  • Page 3: Safety Information

    If this manual is not in your native language and if you have problems understanding the text, we advise you to contact your Varian office for assistance. Varian cannot accept responsibility for any damage or injury caused by misunderstanding of the information in this manual.
  • Page 4 Indicates instrument contains parts that can be damaged by Static discharge electrostatic discharge. Take care for proper grounding Warning before handling. Touching this item may result in damage to the instrument Do not touch or personal injury. Page 4 User Manual CP-4900 Micro-GC Extension Box Varian, BV.
  • Page 5: General Safety Precautions

    It is the responsibility of the Customer to inform Varian Customer Support Representatives if the instrument has been used for the analysis of hazardous biological, radioactive, or toxic samples, prior to any instrument service being performed or when an instrument is being returned to the Service Center for repair.
  • Page 6 12. Never try to repair or replace any component that is not described in this manual without the assistance of a Varian service engineer. Unauthorized repairs or modifications will result in rejection of warranty claims.
  • Page 7: Spare Parts Availability

    Spare Parts Availability Service Availability It is the policy of Varian to provide operational spare parts for any instrument and Varian provides a variety of major accessory for a period of five (5) years after shipment of the final production services to support its customers run of that instrument.
  • Page 9: Table Of Contents

    Table of contents Table of contents Varian Analytical Instrument Warranty ..................2 Hardware Products ......................... 2 Software Products ........................2 Remedies ..........................2 Limitation of Warranty......................2 Limitation of Remedies and Liability ..................2 Safety Information........................3 Information ..........................3 Operating Instructions ......................
  • Page 10: Table Of Contents

    Table of contents Shipping instructions ......................11 Cleaning instructions ......................11 Disposal instructions ......................11 Page 2 User Manual CP-4900 Micro-GC Varian, Inc.
  • Page 11: Introduction

    Reference Introduction Congratulations and thank you for purchasing the Varian BV. CP-4900 Micro- GC Extension Box. The CP-4900 Micro-GC Extension Box is used to bring the CP-4900 Micro-GC more additional in-outputs. For problems or questions about your CP-4900 Micro-GC Extension Box, please contact your nearest Varian subsidiary or Varian representative.
  • Page 12: Pre-Installation Requirements

    Reference Pre-installation requirements In order to assure a quick, safe and uncomplicated installation, we kindly request you to make provisions as stated below before our Varian service engineer will install your instrument(s). Environmental requirements The CP-4900 Micro-GC Extension Box is intended for indoor use.
  • Page 13: Cp-4900 Micro-Gc Extension Box Installation

    Inspect the CP-4900 Micro-GC Extension Box and accessories carefully for damage or signs of rough handling. Report damage to the carrier and to your local Varian office. Check the packing list to see if you have received all that you require.
  • Page 14 Reference Cable connectors CD-Rom Package contents slip Page 4 User Manual CP-4900 Micro-GC Extension Box Varian, BV.
  • Page 15: Connect Extension Box

    To connect the Extension Box to the CP-4900 Micro-GC use the included cables and connect according the picture below. Always connect both cables! CP-4900 Micro-GC Male Extension Box Female Male Female Varian, BV. User Manual CP-4900 Micro-GC Extension Box Page 5...
  • Page 16: External Connections

    +12 VDC out ( electronic fused max 500 mA) +5 VDC out (electronic fused max 500 mA) The CP-4900 Micro-GC reacts, when “Digital IN” signals will be connected to Ground (GND). Page 6 User Manual CP-4900 Micro-GC Extension Box Varian, BV.
  • Page 17: Digital Out

    This contact will follow instrument status ("Ready LED" in front) GC relay 1 GC relay 2 Digital output 1 (Not defined) Digital output 2 (Not defined) All relay contacts: maximum 1A-24 VDC Varian, BV. User Manual CP-4900 Micro-GC Extension Box Page 7...
  • Page 18: Analog In

    ANALOG IN ANALOG IN Analog input-1 0-10 Volt Analog input-2 0-10 Volt Analog input-3 0-10 Volt Analog input-4 0-10 Volt Analog input-5 0-10 Volt Analog input-6 0-10 Volt AGND AGND Page 8 User Manual CP-4900 Micro-GC Extension Box Varian, BV.
  • Page 19: Relay 1-4

    Reference Relay 1-4 RELAY 1-4 RELAY 1-4 Relay 1 Relay 2 Relay 3 Relay 4 All relay contacts: maximum1A-24 VDC Varian, BV. User Manual CP-4900 Micro-GC Extension Box Page 9...
  • Page 20: Relay 5-8

    Reference Relay 5-8 RELAY 5-8 RELAY 5-8 Relay 5 Relay 6 Relay 7 Relay 8 All relay contacts: maximum 1A-24 VDC Page 10 User Manual CP-4900 Micro-GC Extension Box Varian, BV.
  • Page 21: Cleaning Instructions

    Be careful not to get water on the electronics components. • Do not use compressed air to clean. Disposal instructions Disposal must be carried out in accordance with all (environmental) regulations applicable in your country. Varian, BV. User Manual CP-4900 Micro-GC Extension Box Page 11...

This manual is also suitable for:

Cp-4900 pro

Table of Contents