Hide thumbs Also See for CP-4900:

Advertisement

Quick Links

CP-4900 Micro-GC
North/South America
2700 Mitchell Drive
Walnut Creek
94598 California, USA
Tel: ++(1)9259392400
Fax: ++(1)9259452360 or
++(1)9259452344
© 2002 Varian, Inc. All Rights Reserved.
Power Supply
User Manual
Europe
P.O. Box 8033
4330 EA Middelburg
The Netherlands
Tel: ++(31)118671000
Fax: ++(31)118623193
Printed in the Netherlands
Varian B.V.
Herculesweg 8
4330 EA Middelburg
The Netherlands
Australia/East Asia
679 Springvale Road
Mulgrave, Victoria 3171
Australia
Tel: ++(61)395607133
Fax: ++(61)395607950
CP501267 Rev. 01 March 2002

Advertisement

Table of Contents
loading

Summary of Contents for Varian CP-4900

  • Page 1 4330 EA Middelburg Mulgrave, Victoria 3171 94598 California, USA The Netherlands Australia Tel: ++(1)9259392400 Tel: ++(31)118671000 Tel: ++(61)395607133 Fax: ++(1)9259452360 or Fax: ++(31)118623193 Fax: ++(61)395607950 ++(1)9259452344 © 2002 Varian, Inc. All Rights Reserved. Printed in the Netherlands CP501267 Rev. 01 March 2002...
  • Page 2: Software Products

    Support Representative to the site or by authorizing the Customer to return the defective accessory or instrument to Varian or to send it to a designated service facility. The Customer shall be responsible for loss or damage in transit and shall prepay shipping cost.
  • Page 3: Spare Parts Availability

    Spare Parts Availability Service Availability It is the policy of Varian to provide operational spare parts for any instrument and Varian provides a variety of major accessory for a period of five (5) years after shipment of the final production services to support its customers run of that instrument.
  • Page 4: Table Of Contents

    CONTENTS VARIAN ANALYTICAL INSTRUMENT WARRANTY ........2 ....................2 ARDWARE RODUCTS ....................2 OFTWARE RODUCTS ......................2 EMEDIES ..................... 2 IMITATION OF ARRANTY ................2 IMITATION OF EMEDIES AND IABILITY ..................3 PARE ARTS VAILABILITY .................... 3 ERVICE VAILABILITY SAFETY INFORMATION ................... 1 ....................
  • Page 5: Safety Information

    If this manual is not in your nature language and if you have problems understanding the text, we advise you to contact your Varian office for assistance. Varian cannot accept responsibility for any damage or injury caused by misunderstanding of the information in this manual.
  • Page 6 Indicates instrument contains parts that can be damaged by Static discharge electrostatic discharge. Take care for proper grounding Warning before handling. Touching this item may result in damage to the instrument Do not touch or personal injury. Page: 2 User manual CP-4900 Micro-GC Power Supply Varian, Inc.
  • Page 7: General Safety Precautions

    This instrument is designed for use in combination with the CP-4900 Micro-GC. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
  • Page 8 10. Never try to repair or replace any component that is not described in this manual without the assistance of a Varian service engineer. Unauthorized repairs or modifications will result in rejection of warranty claims.
  • Page 9: Introduction And Initial Operation

    Congratulations and thank you for purchasing the Varian, Inc. CP-4900 Micro- GC Power Supply used in combination with the CP-4900 Micro-GC. This Power Supply must only be used in combination with the CP-4900 Micro- GC model. This Power Supply is tailored to meet the power needs of the CP-4900 Micro-GC model.
  • Page 10: Unpacking

    Power Supply input 80 Vac to 130 Vac or 180 Vac to 260 Vac (autoranging) 47 to 63 Hz 130W output 12.0 Vdc Mains cable with plug 220 Vac Mains cable with plug 110 Vac Mains cable with plug 240 Vac Page: 2 User manual CP-4900 Micro-GC Power Supply Varian, Inc.
  • Page 11: Pre-Installation Requirements

    CP-4900 Micro-GC Power Supply and the peripheral instruments which may be installed near it. Allow 10-20 cm of space at the sides and rear of the CP-4900 Micro- GC Power Supply to permit free air circulation.
  • Page 12: Power Source

    The mains network should be properly grounded. Installation Category (overvoltage category): II Power The Micro-GC CP-4900 requires 12V Vdc, 130 W. For more details refer to the User manual Micro-GC CP-4900 Power Supply (CP501265). Page: 4 User manual CP-4900 Micro-GC Power Supply...
  • Page 13: Setting Up The Power Supply

    Introduction and initial operation Setting up the Power Supply 1. Check if the Power Supply is corresponding with the CP-4900 Micro-GC (see table below). Micro-GC Mains voltage Power Supply Cables Power Supply CP740159 Check power connector 230 VAC With mains cable CP72103...
  • Page 14: Cleaning Instructions

    Be careful not to get water on the electronics components. • Do not use compressed air to clean. Disposal instructions Disposal of the Power Supply must be carried out in accordance with all (environmental) regulations applicable in your country. Page: 6 User manual CP-4900 Micro-GC Power Supply Varian, Inc.
  • Page 15: Specifications Cp-4900 Power Supply

    TUV file No. S9954867 Approved RFI/EMC standard In compliance with CISPR22 (EN55022), Class B and FCC class B Dimensions 178 x 95 x 63.5 mm (LxWxH) Weight 1 kg approx. Varian, Inc User manual CP-4900 Micro-GC Power Supply Page: 7...

Table of Contents