ERRoR CoDES
(ConT.)
DISPLAY
"E-20-A"
Pressure Switch failure
Wiring problem
"FAN SENSOR
I/O board failure
STUCK
CLOSED"
Pressure switch failure/
hose loose
"E-20-B"
Draft fan failure/ low
"NO DRAFT"
voltage
"CHECK FAN"
Flue or hood
obstruction
Failure to ignite/ no
flame sense
"E-20-D"
IGNITION
FAILURE"
Slow heat recovery
"E-21"
Burner not igniting
"E-22"
"NO HEAT"
"CHECK GAS
VALVE"
Programming failure
"E-41 " / "E-46"
Analog converter
chip or 12 volt supply
"E-47"
failure
"E-48"
Input system error
Temperature input
"E-54-C"
error
AIF PC board not
"E-60"
communicating with
"FILTER IN
control PC board
USE"
Drain valve jumper
"E-70C"
wire missing or
disconnected
"E-83-A"
Pressure too high
"E-83-B"
Pressure too high
Sept. 2013
CAUSE
If fan is not running, have pressure switch checked; should
be open circuit if no air pressure
If fan is running, wiring error, or relay on I/O board closed
Press power button to vat off and back on again, if E-20-B
persists, have pressure switch checked; should be open
circuit if no air pressure; make sure hose is connected to fan
and pressure switch
Have draft fan checked; low voltage going to fan
Check the fryer flue and hood system for obstructions
Press power button to vat off and back on again, if E-20-D
persists, check gas line connections; check gas shut-off valve;
have ignition module checked; gas valve checked; flame
sensor gap checked; gas valve and ignition module wiring
checked
Have a certified service technician check the fryer for correct
voltage to the unit; have heat circuit checked; have unit
checked for loose or burnt wire
Have gas valve and heat circuit checked
Press power button to vat off and back on again, if any of
the error codes, have the controls re-initialized; if error code
persists, have the control board replaced
Press power button to vat off and back on again, if "E-47"
persists, have the I/O board, or the PC board replaced; if
speaker tones are quiet, probably I/O board failure; have the
I/O board replaced
Have PC board replaced
Turn switch to OFF, then back to ON; have control PC board
replaced if "E-54C" persists
Press power button to turn vat off, wait 15 seconds, and turn
back on again. If "E-60" persists, have connector between
the PC boards checked; replace AIF PC board or control PC
board, if necessary
Have the jumper wire checked on the PC board at drain
switch interlock position
Check filter system in Vat #1
Check filter system in Vat #2
CORRECTION