Specifications; Operating Heater - Procom PCK110VT Owner's Manual

Portable forced air heaters
Hide thumbs Also See for PCK110VT:
Table of Contents

Advertisement

Available languages

Available languages

Output Rating
Fuel (all models)
Fuel Tank Capacity (gal/liter)
Fuel Consumption
(gal/liter per hr.)
Pump Pressure (PSI)
Electric Requirements
Amperage (Normal Run)
Typical Motor Speed (RPM)
Motor Horsepower
Shipping Weight (lbs / kg)
Heater Weight without
Fuel (approx) (lbs / kg)
WARNING: Use only kero-
sene, #1/#2 diesel/fuel oil, JET
A or JP-8 fuels to avoid risk
of fire or explosion. Never
use gasoline, oil drained from
crankcases, naphtha, paint
thinners, alcohol or other highly
flammable fuels.
Use only kerosene, #1/#2 diesel*/fuel oil,
JET A, JP-8 fuels. Heavier fuels such as No.
2 fuel oil, No. 2 diesel fuel may also be used
but will result in:
• noticeable odor
WARNING: Provide a fresh air
opening of at least three square
feet (2,800 square cm) for each
100,000 BTU/HR rating. Provide
extra fresh air if more heaters
are being used. The minimum
ventilation requirements must
be followed to avoid risks as-
sociated with carbon monoxide
poisoning. Make certain these
requirements are met prior to

operating heater.

6

SPECIFICATIONS

110 Model
80K-110K
Use only kerosene, #1/#2 diesel*/fuel oil, JET A or JP-8 fuels
5.5 / 20.8
0.82 / 3.1
6.9 (hot)
120 V/60 HZ 120 V/60 HZ 120 V/60 HZ 120 V/60 HZ
2.9
3400
1/4
42 /19
36 / 16.3
FUELS
• additional fuel filter maintenance
* Use of #2 diesel/fuel oil in extreme cold
Do not use fuels heavier than No. 2 grade
or heavy oils such as oil drained from crank-
cases. These heavy oils will not ignite properly
and will contaminate the heater.
IMPORTANT: Use a KEROSENE ONLY (blue)
or DIESEL ONLY (yellow) storage container.
Be sure storage container is clean. Foreign
matter such as rust, dirt or water will cause the
ignition control assembly to shut down heater.
Foreign matter may also require heater's fuel
system to be frequently cleaned.
VENTILATION
Example: A 220,000 Btu/Hr (64.5 kw) heater
requires one of the following:
• a two-car garage door [16 feet (4.88 meter)
• a single-car garage door [9 feet (2.74 me-
• two, 30" (76.2 cm) windows raised 16"
www.usaprocom.com
160 Model
175 Model
110K-160K
125K-175K
10 / 37.9
10 / 37.9
1.19 / 4.5
1.3 / 4.9
6.7 (hot)
6.8 (hot)
3.2
3.4
3400
3400
1/4
1/4
71 /32.2
71 / 32.2
60.5 / 27.4
60.5 / 27.4
temperatures may require nontoxic anti-icer
additives.
opening] raised 5" (12.7 cm)
ter) opening] raised 9" (22.9 cm)
(40.6 cm)
220 Model
160K-220K
14 / 53
1.64 / 6.2
8.4 (hot)
4.6
3400
1/4
77 / 35
66 / 29.9
160108-01

Hide quick links:

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PCK110VT and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF