Sinclair GSH-60IRA Manual page 15

Air-to-water heat pump
Hide thumbs Also See for GSH-60IRA:
Table of Contents

Advertisement

AIR-TO-WATER HEAT PUMP
Code
Function description
Setting temperature selection:
Selection for setting temperature
1
as room temperature or outflow
water temperature
2
Forced Operation
Celsius/Fahrenheit switching:
3
Display temperature in Celsius or
Fahrenheit
Thermostat
4
Enable/disable
Enable/disable of quick sanitary
5
heating
Enable/disable of disinfection
6
operation
7
Enable/disable of holiday mode
Setting priority when under cooling
demand and sanitary water
8
heating demand are required at
the same time
Setting priority when under
heating demand and sanitary
9
water heating demand are
required at the same time
Setting status of back-up heater
10
(indoor unit)
11
Setting start date of disinfection
Table of user function parameter
0: leaving water
temperature
1: room temperature
0: no Forced operation
1: Forced cooling
operation
2: Forced heating
operation
0:Celsius
1:Fahrenheit
0: disable
control
is
1: enable
0: disable
1: enable
0: disable
1: enable
0: disable
1: enable
0: priority to cooling
1: priority to water tank
heating
0: priority to heating
1: priority to water tank
heating
1: use half capacity of
Back-up heater(3kW)
2: use full capacity of
Back-up heater(6kW)
0: Sunday
1: Monday
9
CONTROL PANEL MENU
Detail
0~1(default: 0)
0~2(default: 0)
0~1(default: 0)
0~1(default: 0)
0~1(default: 0)
0~1(default: 0)
0~1(default: 0)
0~1(default: 0)
0~1(default: 0)
1~2(default:1)
0~6(default: 6)
Range