USER´S MANUAL
AIR TO WATER HEAT PUMP
INDOOR UNIT - HYDROBOX
GSH-IRAD

Advertisement

Table of Contents
loading

Summary of Contents for Sinclair GSH-IRAD

  • Page 1 USER´S MANUAL AIR TO WATER HEAT PUMP INDOOR UNIT - HYDROBOX GSH-IRAD...
  • Page 2 “Original instructions”  ...
  • Page 3: Quick Setup

    QUICK SETUP Descriptions of the controls The upper bar displays time, successfully connected Sinclair Route (cloud) service and Ethernet connection. Object section Overview section Displays mode of Displays important heating / cooling, object temp., temperatures and parameters, circulator state, object state,...
  • Page 4: Important Notice

    Dear consumer, thank you for purchasing the heat pump GSH-IRAD. We hope you will be satisfied with the device which shall bring heat comfort to your house.The pump is a quite complicated device therefore pay high attention to this manual,please. The manual shall make you familiar with using, placement, construction and further information.
  • Page 5: Storage And Transportation Conditions

    Temperature - 20 - +35 °C Humidity max 90% Outdoor unit has to be stored and transported vertically in an original package, avoid damage of fragile parts Indoor unit GSH-IRAD Dust-free, non-aggressive environment Temperature +5 to +45 °C Humidity max 70%...
  • Page 6: Principle Of Operation

    6. PRINCIPLE OF OPERATION A heat pump is a device gaining low-temperature energy from a selected source and transforming it to a higher temperature level. A heat pump air-water system utilizes heat of surrounding air. Its core is a high-performance compressor which presses down the refrigerant in a hermetic circuit and expands it while using convenient features of the cooling medium.
  • Page 7 Outdoor unit GSH-70/80ERAD Outdoor unit GSH-110/130ERAD...
  • Page 8 2000 > 8. CONNECTING OF REFRIGER T A ION CIRCUIT Only authorized service can connect he refrigeration circuit (see Installation). ARNING! Do not try to connect the circuit on your own! There is a threat of a serious injury The refrigerant is under pressure of 4,5MPa and temperature is up to -50 °C.
  • Page 9: First Start Of The Heat Pump

    BIVALENT SOURCE Heat pumps GSH-IRAD contain integrated electric boiler of capacity 6kW. The boiler compensates power loss of the heat pump at extreme conditions. When external bivalent boiler is used, it is necessary to equip it with all safety elements (temperature protection, pressure valve, el. protection). The added bivalent source is controlled by the heat pump only passively.
  • Page 10 10. Settings and service of regulator GSH-IRAD Unity Color Description of the control panel GSH-IRAD Basic controls: For basic controls of the heat pump use graphical touch panel. Main menu (press button „MENU”) Graphs of important values Main screen - summary. Used for switch on / off Heat pump, DHW heating.
  • Page 11 Description of sections - Overview - main screen The upper bar displays time, successfully connected Sinclair route (cloud) service and Ethernet connection. Object section DHW section Overview section Displays mode of Displays temp. of Displays important temperatures and heating / cooling,...
  • Page 12 Description of sections - Overview - main screen Section - More... 2. circ - secondary circuit mixing valve opening 2. equi. - temperature computed by equithermal curve for secondary circuit 2. outp. - output water temperature for secondary circuit Outdoor temp. - outdoor temperature Comp.
  • Page 13 In GSH-IRAD heat pump are used two tools for comfort settings of equithermal curve: 1. Neo Equitherm - Automatic correction write down desired adjustment of heating water temperature without you have to think about which value and how much to change.
  • Page 14 Description of sections - Object pg. 2 Sec. equitherm. T - actual temperature computed by equithermal curve for secondary circuit and access to equithermal curve settings (same principle as the primary circuit) Attenuation time schedule - attenuation settings for output water temperature and potential outdoor unit power limit after a certain time.
  • Page 15 Description of sections - Settings pg. 1 Current limit per 1 phase - at one phase units may experience overloading when runs together with bivalent source; this function cause that first stage of bivalent source will not be used for bivalent operation Secondary circuit - define if the secondary circuit control is used (external mixing valves) Outdoor unit max power - enable to set outdoor unit maximal power (mainly used for noise reduction) Only in the attenuation - outdoor unit power limit is active only when attenuation is active...
  • Page 16 10. SERVICE EXTENSIONS POSSIBILITIES ETHERNET 100Mbit FD WI-FI WI-FI INTERNET INTERNET WEB SERVER SERVICE To connect to the heat pump web site the controller must be plugged into an Ethernet network and configured correctly. Then you can access the web interface from the computer Internet browser with support of XML standard. Enter IP address of heat pump into your browser address bar.
  • Page 17 SINCLAIR ROUTE SERVICE Sinclair Route is new service of GSH-IRAD heat pump, which secure user access to web server through the Internet network without need of public IP address and exactly router mapping. The heat pump needs only Internet connection as well as any computer.
  • Page 18: Maintenance

    12. MAINTENANCE This heat pump because of its construction requires really low maintenance. The basic maintenance will be provided by service company once a year. During this service will be checked all crucial parts of the heat pump. Especially the amount of refrigerant in circuit and refrigerant circuit function. It´s important to check outdoor unit exchanger.
  • Page 19: Protective Function

    14. PROTECTIVE FUNCTION Protective Description Note / function variable Freeze Static (output water If the indoor unit is connected to power protection temperature lower than 5°C) supply, output water temperature is monitored. When it is lower then 5°C, so circulator and first stage of bivalent (2 kW) are switched ON.
  • Page 20 Protective Description Note/ function variable Sensor control Critical sensors - output If temperature sensor is out of range (-50 to Error autoreset water, input water 120°C) critical error is signalized and heat max. 5 times pump stops operation. Other sensors Error is signalized, but have not got any influence to primary heat pump operation.
  • Page 21 DIMENSIONS Indoor unit 565 mm 305 mm Mounting plates POSITION IS NOT USED COULD BE USED MIRROR...
  • Page 22 Errors States and errors Section - Status Errors Code of states and errors - four-digit code (read from left) 1. digit: 1 - Freeze protection (output water temperature dropped below safe limits) 2 - Insufficient water flow (water flow dropped below safe limits) 3 - Outdoor unit disorder 4 - Low water pressure (water pressure dropped below 0,9 Bar) 5 - Faulty temperature sensor MX (communication unit)
  • Page 24 The value GWP: 2088 GWP = Global Warming Potential In case of quality problem or other please contact your local supplier or authorized service center. Emergency number: 112 PRODUCER SINCLAIR CORPORATION Ltd. 1-4 Argyll St. London W1F 7LD Great Britain www.sinclair-world.com REPRESENTATIVE, TECHNICAL SUPPORT NEPA spol.