Reduced Clearances - Stanley brandon dhw Installation And Commissioning Manual

Oil models
Table of Contents

Advertisement

REDUCED CLEARANCES

Where the flue passes through a combustible mate-
rial a twin wall solid packed insulated chimney con-
nector must be used and must come flush with the
outer surface of the material and run all the way to
the masonry chimney or to the point of termination
of the factory made chimney. (see Fig. 6)
If the cooker is to be installed against combustible
material (e.g. cabineting or wall panelling) a panel of
1 /2
12mm (
") thickness non-combustible insulation
board the size of the appliance must be fitted
between the cooker and the combustible material.
The insulation board used must not contain
asbestos or ceramic. (See Figs. 7 & 8)
The clearances for non-combustible materials can
then be observed (see Fig.4)
An optional hob filler strip can be fitted between the
Stanley and adjacent units. Refer to fig.7.
Fig.7
Fig.5
Fig.8
Fig.6
Fig.9
7
Fig.7a

Advertisement

Table of Contents
loading

This manual is also suitable for:

Brandon dry

Table of Contents