Sealing; Flue Height; Connections - Stanley brandon dhw Installation And Commissioning Manual

Oil models
Table of Contents

Advertisement

Flue greater than 125mm
(5") Diameter
Fig. 12
Clay Liner
Vermiculite Filler or
comparable material
Flexible Flue
Liner 150mm (6")

SEALING

This cooker and flue system operate under a posi-
tive pressure, it is essential that all flue joints are
tightly sealed against flue gas leakage and tested
accordingly (see Fig. 11 & 12).
There is a flue pipe collar available which surrounds
the flue pipe where it meets the wall, giving a tidier
finish to a tiled background (see fig. 9). The flue
pipe collar is available as an optional extra, to order.
Fig.13
Bend
Approved Flue
Terminal
Refer to Flue Assembly Instructions sheets.

FLUE HEIGHT

The flue must be high enough 4.5 mts. (15ft) mini-
mum measured vertically from the appliance outlet
to the top of the flue terminal, to allow the flue gases
to vent into the clear air, away from the turbulence
that may be caused by roof structures, other chim-
ney stacks, etc. The terminal position should be in
accordance with B.S. 5410 and the current Building
Regulations.
Sealing &
Clamping Plate
If it is necessary to offset the chimney the recom-
mended angle is 60° to the horizontal and the statu-
tory minimum is 45° (see fig. 14).
Note: Never connect to a chimney or flue system
Seal Flue
serving another appliance.
Connector
Fig.14

CONNECTIONS

A cast iron 90° bend with cleaning door is supplied
with the cooker, along with a cast iron spigot for con-
nection to a vertical flue pipe. A vertical cast iron
outlet pipe with cleaning door is available to order. A
flexible flue adaptor is supplied, this is to connect
the cooker bend or straight pipe to the chimney
liner.
Note: Maximum horizontal length should not be
more than 300mm (12") where the appliance spigot
or flue pipe protrudes into the chimney, care should
be taken to ensure that it does not block the chim-
ney.
ALL FLUE CONNECTIONS MUST BE THOR-
OUGHLY SEALED.
9
Fig.13a
Gasket
Cleaning
Plate
Gasket
Collar
Pipe
Spigot
Gasket
Collar

Advertisement

Table of Contents
loading

This manual is also suitable for:

Brandon dry

Table of Contents