Removal Of Fan Motor - Daikin FTXS30LVJU Service Manual

Inverter pair ftxs-l series fdxs-l series
Hide thumbs Also See for FTXS30LVJU:
Table of Contents

Advertisement

SiUS091133
7.4

Removal of Fan Motor

Procedure
Step
1
Cut the clamps at 2
locations.
2
Remove the 2 lower
screws first.
3
Then, remove the 2
upper screws.
4
Remove the fan motor.
Removal Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
2
1
Fan motor
Outdoor Unit: RKS30/36LVJU, RXS30/36LVJU
Preparation
 Remove the electrical box
according to the "Removal of
Electrical Box".
(R9630)
 Be sure to remove the lower
screws first. If the top screws
are removed first, the fan motor
may tilt down or fall and cause
injury because its center of
gravity is shifted to the front.
(R6442)
 When reassembling, make sure
that the wire harness is facing
downward.
Harness
(R6443)
Points
(R6444)
374

Hide quick links: