Outdoor Unit: RXS09/12LVJU
Step
3
Heat up the brazed part
of the suction side and
disconnect it.
4
Lift the compressor up
and remove it.
289
Procedure
Suction side
Points
Note:
 Never use a metal saw to cut
pipes because the sawdust may
enter the circuit.
 When withdrawing the pipes, be
careful not to pinch them firmly
with pliers. The pipes may get
deformed.
 Provide a protective sheet or a
steel plate so that the brazing
flame cannot influence
peripheries.
(R12032)
 Be careful so as not to burn the
compressor terminals, the name
plate, the heat exchanger fins.
(R7254)
Removal Procedure