SiUS091133
4.2

Removal of Electrical Box

Procedure
Step
1
Disconnect the
connector for the
overload protector
[S40].
2
Disconnect the
connector for the four-
way valve coil [S80].
3
Disconnect the 2
connectors for the
reactor.
Removal Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Outdoor Unit: RXS09/12LVJU
Points
Preparation
 Remove the outer panels and
disconnect the connector for the
fan motor according to the
"Removal of Outer Panels / Fan
Motor".
[S40]
(R16924)
[S80]
(R16925)
 When reassembling, you can
connect the 2 harnesses in
either way regardless of the
color.
(R16926)
270